handover:aov035 [2019/05/14 17:47]
Warren Hankey
handover:aov035 [2019/05/15 11:15] (current)
Md. Momtazur Rahman
Line 5: Line 5:
 Disk VSN: HOB+0125/​32000/​1024 | Data volume at beginning: 15.9 TB Disk VSN: HOB+0125/​32000/​1024 | Data volume at beginning: 15.9 TB
  
-   * 1725UT - Cryo monitoring system not working at Ho (ERROR ma   -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that seems to be causing problems too. (Patrick)+   * 1725UT - Cryo monitoring system not working at Ho (ERROR ma   -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick) 
 +   * 1725UT - ''​wx''​ command not working. Returning the following errors: (Patrick) 
 +     * ''​wx#​Problem connecting to metserver socket''​ 
 +     * ''​wx#​Illegal error class code: 0xffffffff''​
    * 1730UT - Experiment started OK (Patrick)    * 1730UT - Experiment started OK (Patrick)
 +   * 1842UT - Windstowed from 18:42 - 19:25. (Patrick)
 +     * Missed scans: 134-1841b thru 134-1924b
 +   * 1925UT - Field system time out of sync (''​ERROR sc  -13 setcl: formatter to FS time difference 0.5 seconds or greater''​). Fixed by running ''​sy=run setcl offset''​ in oprin. (Patrick)
 +     * Also at 20:46, 22:47, 22:52
 +   * 2300UT - Fixed rxmon/​cryomon (ERROR ma   -4 Device rx timed-out on response) by resetting TTY distributor with "​reset"​ switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett)
 +   * 1200UT- Onsource status is slewing (Momtaz)!
  
 **Katherine 12m** **Katherine 12m**
Line 12: Line 21:
 Disk VSN:​HOB+0015 | Data volume at beginning: 0.0 GB Disk VSN:​HOB+0015 | Data volume at beginning: 0.0 GB
  
 +   * 1730UT - No system temperature measurements. Restarted DBBC pc, which fixed it. (Patrick)
    * 1730UT - Experiment started OK (Patrick)    * 1730UT - Experiment started OK (Patrick)
  
Line 19: Line 29:
  
    * 1730UT - Experiment started OK (Patrick)    * 1730UT - Experiment started OK (Patrick)
 +   * 1730UT - no connection to Yg maser (Patrick)
  
  