* 1725UT - Cryo monitoring system not working at Ho (ERROR ma -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick) | * 1725UT - Cryo monitoring system not working at Ho (ERROR ma -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick) | ||
- | * 1725UT - ''wx'' command not working. Returning ''wx#Problem connecting to metserver socket, wx#Illegal error class code: 0xffffffff'' (Patrick) | + | * 1725UT - ''wx'' command not working. Returning the following errors: (Patrick) |
+ | * ''wx#Problem connecting to metserver socket'' | ||
+ | * ''wx#Illegal error class code: 0xffffffff'' | ||
* 1730UT - Experiment started OK (Patrick) | * 1730UT - Experiment started OK (Patrick) | ||
* 1842UT - Windstowed from 18:42 - 19:25. (Patrick) | * 1842UT - Windstowed from 18:42 - 19:25. (Patrick) | ||
Line 13: | Line 15: | ||
* Also at 20:46, 22:47, 22:52 | * Also at 20:46, 22:47, 22:52 | ||
* 2300UT - Fixed rxmon/cryomon (ERROR ma -4 Device rx timed-out on response) by resetting TTY distributor with "reset" switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) | * 2300UT - Fixed rxmon/cryomon (ERROR ma -4 Device rx timed-out on response) by resetting TTY distributor with "reset" switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) | ||
+ | * 1200UT- Onsource status is slewing (Momtaz)! | ||