   * 18:00 UT - Experiment started OK (vk)   * 18:00 UT - Experiment started OK (vk)
   * 06:15 UT - brief network latency spike caused the computer acu time difference to raise to ~1s. Resolved after 2 min.   * 06:15 UT - brief network latency spike caused the computer acu time difference to raise to ~1s. Resolved after 2 min.
-  * 12:36 UT - difference between maserdelay and clkoff reached -0.5 us. Counter didn't help. Ran fmset at the end of the scan, didn't help... (Ellen)+  * 12:36 UT - difference between maserdelay and clkoff reached -0.5 us. Counter didn't help. Ran fmset at the end of the scan, didn't help. So I halted the schedule at 12:52 UT shutdown the DBBC and reconfigured it and that fixed it(Ellen) 
 +  * 12:57 UT - schedule resumed. Missed scan 127-1251. (Ellen) 
 +  * 13:41:04 - Large difference between formatter and maser delays. Resynced clocks though is drifting slowly still. No scans missed (Ross).
  
 **Yarragadee 12m:** **Yarragadee 12m:**