aua029

Hobart 26m:

Disk VSN: MPI+1610

Data volume at beginning: 5158 GB

  • 23:30UT - Schedule file was not being produced with the slogit script, Jamie drudged it manually (Patrick)
  • 00:00UT - Experiment started OK (Patrick)
  • 05:17UT - ALARM: error fl -1 previous source in this schedule not reached before new source was commanded (Patrick)
  • 05:48UT - WARNING: SX receiver parameter pres out of range. Use rxmon command to confirm. Reported receiver position: X: -255.8mm, Y: 252.2mm, Z: 18.6mm. Called Jamie and he says if live page shows correct values (which it does) it's all fine (Patrick)
  • 05:50UT - Vacuum pressure leak for receiver cooling system, can't fix for this experiment. Notified Brett, will try to fix on Monday. Rest of experiment will run with warmed receiver, from scan 280-0552 or so. (Patrick)

Katherine 12m:

Disk VSN: HOB+0100

Data volume at beginning: 9411 GB

  • 00:00UT - Experiment started OK (Patrick)
  • 13:10:03UT ALARM: Large difference between formatter and maser delays. The times all seem fine and synced in fmset (Ross)

Yarragadee 12m:

Disk VSN: USN-0131

Data volume at beginning: 1 GB

  • 00:00UT - Experiment started OK (Patrick)