This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
handover:aua045 [2018/06/07 09:19] Noor Md Said |
handover:aua045 [2018/06/07 18:03] (current) Noor Md Said |
||
---|---|---|---|
Line 15: | Line 15: | ||
07:30 UT - Noticed autocorrelation spectra was not updating. Checked procedure file (compared to aua043) and noticed it was missing a bunch of procedures (including postob, which produces the spectra). Copied those procedures into the aua045ho.prc file, and reloaded it with ''proc=aua045ho''. Now the spectra are showing up, and they look fine (Patrick) | 07:30 UT - Noticed autocorrelation spectra was not updating. Checked procedure file (compared to aua043) and noticed it was missing a bunch of procedures (including postob, which produces the spectra). Copied those procedures into the aua045ho.prc file, and reloaded it with ''proc=aua045ho''. Now the spectra are showing up, and they look fine (Patrick) | ||
+ | 11:34UT - windstowed: 11:34-11:56 (scans no00183-no00186) (Patrick) | ||
+ | |||
+ | 16:55UT - S/X receiver cryo pressure jumped to above 6 microns Hg, and 70K stage started warming up. No point driving out to Mt. Pleasant to fix it, as experiment only has 1 hour to go. (Patrick) | ||
**Katherine 12m** | **Katherine 12m** | ||
Line 25: | Line 28: | ||
18:18:45 UT Log monitor started to report negative disk usage for some of the scans (mas) | 18:18:45 UT Log monitor started to report negative disk usage for some of the scans (mas) | ||
- | + | 7895 | |
- | 07:00UT - Recieve ''an -103 pointing computer tracking errors are too large'' and ''qo -301 warning: onsource status is slewing!'' at the start of each scan. Telescope is late on source by about 10 seconds each scan. (Patrick) | + | 07:00UT - Recieve ''an -103 pointing computer tracking errors are too large'' and ''qo -301 warning: onsource status is slewing!'' at the start of each scan. Telescope is late on source by a few seconds. (Patrick) |
09:20UT - continuous cal error is safe to ignore according to Warren, so I have changed the Ke alarm_actions.txt to ignore it for this experiment. (Patrick) | 09:20UT - continuous cal error is safe to ignore according to Warren, so I have changed the Ke alarm_actions.txt to ignore it for this experiment. (Patrick) | ||
Line 33: | Line 36: | ||
Disk VSN: MAT +0003/8000 | Data volume at beginning: 0.00 GB | Disk VSN: MAT +0003/8000 | Data volume at beginning: 0.00 GB | ||
+ | |||
+ | Disk 2 VSN: HOB+0051 | Data volume at beginning: 0.00 GB | ||
18:00 UT Experiment started OK (mas) | 18:00 UT Experiment started OK (mas) | ||
Line 40: | Line 45: | ||
18:15:30 UT Halt schedule and tried to sync the seconds decimal for Field System and computer (0.02 micro seconds difference with Mark5) but couldn't sync. Maserdelay and clkoff are OK. Missed scans no00005 & no00006 (mas) | 18:15:30 UT Halt schedule and tried to sync the seconds decimal for Field System and computer (0.02 micro seconds difference with Mark5) but couldn't sync. Maserdelay and clkoff are OK. Missed scans no00005 & no00006 (mas) | ||
- | 07:00UT - Recieve ''an -103 pointing computer tracking errors are too large'' and ''qo -301 warning: onsource status is slewing!'' at the start of each scan. Telescope is late on source by about 10 seconds each scan. (patrick) | + | 07:00UT - Recieve ''an -103 pointing computer tracking errors are too large'' and ''qo -301 warning: onsource status is slewing!'' at the start of each scan. Telescope is late on source by a few seconds. (patrick) |
+ | |||
+ | 12:43UT - Module MAT+0003 ran out of disk space. Called Yg, new module put in (HOB+0051). Schedule resumed at 12:50UT. Scan missed: no00194 (Patrick) | ||