This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
handover:aua072 [2021/01/20 01:06] Warren Hankey |
handover:aua072 [2021/01/20 06:08] (current) Warren Hankey |
||
---|---|---|---|
Line 9: | Line 9: | ||
* 2242UT - encoder glitch? drives shut down during scan 019-2242 drives restarted and slewed to next source (Warren) | * 2242UT - encoder glitch? drives shut down during scan 019-2242 drives restarted and slewed to next source (Warren) | ||
* 2300UT - dead limit switch activated near zenith. mechanical fault. schedule halted (w) | * 2300UT - dead limit switch activated near zenith. mechanical fault. schedule halted (w) | ||
- | * 2357UT - fixed problem on antenna, this was so-called "encoder glitch" that had occurred weekly! schedule resumed (w) | + | * 2357UT - fixed problem on antenna. schedule resumed. so-called "encoder glitch" occurring weekly was limit switch activating momentarily near X=0.0 (w) |