aust43

DISKS:

hb HOB+0119
ke HOB+0122
yg HOB+0120

Ke

1000 UTC: Int. T. reading red at 55 C. The internal temperature of the maser unit has risen to warning levels. Monica shows that the maser room temperature has risen since about 0 UTC on 27/8 reaching a peak at 0800 UTC and is now falling again. Brett informed. Martin to investigate in the morning (~2000 UTC).

1200 UTC: Int. T. now at 48 C and warning light off in maser monitor.

1300 UTC: Delay difference has been drifted since start of experiment. This seems to be coming from the formatter.

1315 UTC: Drift rate increased. Rebooting and formatting the DBBC.

2208 UTC: fmout seems to have been stable since UT18:00

1330 UTC: Resumed after reboot. Monitoring offsets.

1750 UTC: Delay difference drifting again. Trying another reconf.

2209 UTC: fmout seems to have been stable since UT18:00

0115 UTC: Large difference between formatter and maser delays. Halted schedule to run fmset. This did not fix the problem. However, the delays look stable so leaving it be for now. Schedule starting again at UT01:40.