handover:c1704_v1704 [2017/12/01 23:05]
Noor Md Said
handover:c1704_v1704 [2017/12/01 23:08] (current)
Noor Md Said
Line 7: Line 7:
 Date volume at beginning: 1.674 GB Date volume at beginning: 1.674 GB
  
-  ​00:02:53 UT - experiment started OK (mas) +  ​00:02:53 UT - experiment started OK (mas) 
-  ​Received several alarms: "​warning error m5 -906: already off. warning:​error m5 -906 mark5 return code 6: inconsistent or  +  ​Received several alarms: "​warning error m5 -906: already off. warning:​error m5 -906 mark5 return code 6: inconsistent or conflicting request",​ occurred at 03:15:25 UT, 03:17:37 UT, 03:24:41 UT and 03:33:30 UT (mas) 
- conflicting request",​ occurred at 03:15:25 UT, 03:17:37 UT, 03:24:41 UT and 03:33:30 UT +  ​Missed scans at 03:24:00 UT till 03:26:00 UT due to windstow ​(mas)
-  ​Missed scans at 03:24:00 UT till 03:26:00 UT due to windstow+
  
  
/home/www/auscope/opswiki/data/attic/handover/c1704_v1704.1512169501.txt.gz · Last modified: 2017/12/01 23:05 by Noor Md Said