User Tools

Site Tools


handover:c1712_v1712

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
handover:c1712_v1712 [2017/12/09 07:53]
Patrick Yates
handover:c1712_v1712 [2017/12/09 23:29] (current)
Patrick Yates
Line 22: Line 22:
 2017.343.06:​48:​58.51;"​Windstowed between 343-06:​33:​46 and 343-06:​48:​46 2017.343.06:​48:​58.51;"​Windstowed between 343-06:​33:​46 and 343-06:​48:​46
 2017.343.07:​06:​06.31;"​Windstowed between 343-06:​53:​02 and 343-07:​05:​55 2017.343.07:​06:​06.31;"​Windstowed between 343-06:​53:​02 and 343-07:​05:​55
-2017.343.07:​22:​43.70;"​Windstowed between 343-07:​20:​27 and 343-07:​22:​39 </​code>​+2017.343.07:​22:​43.70;"​Windstowed between 343-07:​20:​27 and 343-07:​22:​39 
 +2017.343.20:​53:​49.22;"​Windstowed between 343.20:​53:​49 and 343.22:​55:​55 
 +2017.343.23:​28:​47.63;"​Windstowed between 343-23:​24:​35 and 343-23:​28:​31 
 +</​code>​ 
 +  * Antenna got half stuck in windstow between 2017.343.20:​53:​49.22--2017.343.22:​55:​55.59. Restarting schedule and windstow script fixed issue. No alarm. 
 +  * New windstow script is messing up ''​comments.py''​. To auto report windstows and missed scans for c1712ho, download the log to ''/​vlbobs/​ivs/​logs/''​. This can be done using  ''​ scp oper@hobart:/​usr2/​log/​c1712ho.log /​vlbobs/​ivs/​logs/''​ ,manually remove the line ''​2017.343.00:​07:​44.23;"​Schedule resumed after end of wind stow.''​. Run ''​python ask/​comments/​comments_hofix.py''​ to generate the email. Run flogit as per normal but make sure you download a fresh copy of the log. You might have to delete another line if the telescope goes into stow before the exp end but doesnt recover before the exp finishes. Temp workaround until the old anemometer is fixed. (Arwin)
  
  
Line 38: Line 43:
  
      * 0002UT - Experiment ​ started ok. (Ellen)      * 0002UT - Experiment ​ started ok. (Ellen)
 +     * 2017.343.06:​10:​00 UT windstow. The drives failed to recover, manually recovered at  2017.343.06:​25:​25,​ '''​comments.py'''​ will auto report this (Arwin).
 +     * Problem with VNC viewer for maser (14:35:30 UT), so far maserdelay and clkoff values are OK (mas)
 +
  
  
/home/www/auscope/opswiki/data/attic/handover/c1712_v1712.1512806001.txt.gz · Last modified: 2017/12/09 07:53 by Patrick Yates