* 1730UT Experiment started okay (Lim) | * 1730UT Experiment started okay (Lim) | ||
* 1941UT Autocorrelation did not look gook, reprogrammed DBBC and Sync fmset after scan 176-1936, missed scans: 176-1943 and 176-1951. (Lim) | * 1941UT Autocorrelation did not look gook, reprogrammed DBBC and Sync fmset after scan 176-1936, missed scans: 176-1943 and 176-1951. (Lim) | ||
+ | * 2140UT formatter-gps time was constantly drifting since last dbbc reconfiguration. drifted to ~0.9us, Solved by Rebooting mk5 and dbbc. Missed scans: 176-2136, 176-2143, 176-2149(Lim) | ||
+ | * 0422-0511 - Sync Error and associated 1 second offset. No obvious cause. DBBC power cycled and reconfigured. (JMc) | ||
+ | |||
+ | |||