-====== gt05 ====== +====== ​RadioAstron Track, ​gt05 ======
- +
- +
-RadioAstron Track, gt05+
  
 Yarragadee 12m Yarragadee 12m
Line 8: Line 5:
 Observer: Arwin Observer: Arwin
  
-  ​* 0100UT Experiment started OK. Checked with the prc file which loaded ''​rfpic=cross,​direct''​ when ''​schedule=gt05yg''​ was entered. Recording for sband=direct(20v) from 0100 UT onwards. ifa power levels were very high, ifa was approx 39000 whilst ifb was around 29000. See Image 1 below+===== Summary ===== 
 + 
 +  * 01:00:00 - 01:42:14 UT: 20V, no attenuation 
 +  * 01:42:14 - 02:10:51 UT: 14V, 56 dB attenuation 
 +  * 02:10:51 - 02:16:11 UT: 20V, 56 dB attenuation 
 +  * 02:16:11 - 02:20:00 UT: 12V, 56 dB attenuation 
 + 
 +==== Power and attenuation levels in the DBBC ==== 
 +  * RCP: {{ :​handover:​gt05_rcp.png?​200 |DBBC RCP power and attenuation}} 
 +  * LCP: {{ :​handover:​gt05_lcp.png?​200 |DBBC RCP power and attenuation}} 
 +===== Log ===== 
 + 
 +  ​* 0100UT Experiment started OK. Checked with the prc file which loaded ''​rfpic=cross,​direct''​ when ''​schedule=gt05yg,#1''​ was entered. Recording for sband=direct(20v) from 0100 UT onwards. ifa power levels were very high, ifa was approx 39000 whilst ifb was around 29000. See Image 1 below
   * 0142UT Entered ''​rfpic=*,​cross''​. Recording for Sband=cross from 12:42UT onwards. The power levels were under control for this setting, ifa settled around 24800 whilst ifb settled around 29000. See Image 2 below   * 0142UT Entered ''​rfpic=*,​cross''​. Recording for Sband=cross from 12:42UT onwards. The power levels were under control for this setting, ifa settled around 24800 whilst ifb settled around 29000. See Image 2 below
   * 0149UT Noticed the proc file had a comment on the line indicating the switch state. The line read ''"​rpfic=cross,​direct''​ and as such may not have loaded the correct setting and just imported the default ''​rfpic=direct,​direct''? ​   * 0149UT Noticed the proc file had a comment on the line indicating the switch state. The line read ''"​rpfic=cross,​direct''​ and as such may not have loaded the correct setting and just imported the default ''​rfpic=direct,​direct''? ​
/home/www/auscope/opswiki/data/attic/handover/gt05.1478315654.txt.gz · Last modified: 2016/11/05 03:14 by Bryn Emptage