User Tools

Site Tools


handover:hob005

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
handover:hob005 [2016/09/25 17:50]
Lucas Hyland
handover:hob005 [2016/09/25 22:40] (current)
Lucas Hyland
Line 1: Line 1:
 ====== HOB005 ====== ====== HOB005 ======
- 
-Setup was very ambiguous. Is there a wiki-page dedicated to this special setup? 
  
 **Hobart 12m** **Hobart 12m**
  
-AUST/normal setup procedures followed but SNP file wasn'​t/​isn'​t downloaded with drudge. No .sum file either. Only noticed when attempted to start schedule got "ERROR bo -105 Error opening schedule file FMP ? FFF"​. ​Called on-call person and emailed variousIssue remains unresolved.+AUST/normal setup procedures followed but SNP file wasn'​t/​isn'​t downloaded with drudge. No .sum file either. Only noticed when attempted to start schedule got "ERROR bo -105 Error opening schedule file FMP ? FFF". 
 +Turns out proc file had extra ifd=(blank) which, when deleted, allowed a successful drudge. 
 + 
 +Jamie fixed all the problems. 
 + 
 +Disk_module HOB+0.0088. 
 + 
 +First good scan, 269-1909 at 19:09UT disk_pos=1542.798 GBs 
  
 **Hobart 26m** **Hobart 26m**
  
-As per notes on here: (http://​auscope.phys.utas.edu.au/​opswiki/​doku.php?​id=observing:​hohb) the mk5 was swapped over. And schedule started. Initially got nominal response from mk5=dot? So started schedule. Got error "ERROR tc -302 TPICD not set-up: no detectors selected"​. After observer and on-call person attempted to fix, status went from bad to worse and errors concerning wrong mode selected in equip.ctl file started. And disk_record=off no longer worked as "Error m5 -900: Can't record with Mark-5B DOM"​. ​Also unresolved.+As per notes on here: (http://​auscope.phys.utas.edu.au/​opswiki/​doku.php?​id=observing:​hohb) the mk5 was swapped over. And schedule started. Initially got nominal response from mk5=dot? So started schedule. Got error "ERROR tc -302 TPICD not set-up: no detectors selected"​. After observer and on-call person attempted to fix, status went from bad to worse and errors concerning wrong mode selected in equip.ctl file started. And disk_record=off no longer worked as "Error m5 -900: Can't record with Mark-5B DOM"​. ​ 
 + 
 +Started restarting entire setup and Jamie took over and fixed most problems apart from TIPCD error which he said he will work on an update for equip.ctl file. 
 + 
 +Disk_module HOB+1010 
 +First '​good'​ scan 269-1930 at 19:30 UT disk_pos=2602.831 GBs
  
  
/home/www/auscope/opswiki/data/attic/handover/hob005.1474825828.txt.gz · Last modified: 2016/09/25 17:50 by Lucas Hyland