 ====== HOB006 ====== ====== HOB006 ======
  
-**Hobar 26m**+When the hydraulics at Ho failed the following error was in the log monitor but was not setting off an alarm so Lucas wasn't woken up for it. It is not listed in the alarm_actions file
  
-2016.295.18:39:​43.88?​ERROR sp  ​-13 This command ​not supported for your equipment, check equip.ctl..+WARNINGerror fl   -1 previous source in this schedule ​not reached before new source was commanded
  
-2016.295.18:​39:​43.88?​ERROR df -201 Mode must be one of: astro, geo, wastro, test, lba, astro2, or astro3. 
  
-2016.295.18:​39:​44.89?​ERROR di -400 IF module position exceeds number of conditioning modules+**Hobart 26m**
  
-2016.295.18:​39:​44.89?​ERROR sp  ​-13 This command not supported for your equipmentcheck equip.ctl.+disk USN-0085total data pre-recorded 1115.510 GBs
  
-2016.295.18:​39:​45.11?​ERROR m5 -900 : ENOSYS - not implemented ​ +  * Experiment started late, GPIB device continually timed out whilst many errors ensued with control and equip files (Lucas)
- +  * Turns out experiment was being incorrectly drudged due to unique setup (mk5/dbbc)Jamie manually re-drudged and setupxx worked correctlyFirst good scan 295-2040 (Lucas)
-2016.295.18:​39:​45.11?​ERROR m5 -907 MARK5 return code 7: no such keyword +  * Still getting delay difference changing due to GPIB device timeout
- +    * Update, as of 295-2052 after repeated "​counter"​ commands it has fixed itselfMonitoring(Lucas)
-2016.295.18:​39:​45.11?​ERROR m5 -900 : Unknown datasource mark4  +  * I think there is a hydraulics faultThe Live page keeps saying to and keep getting ​command ​'​previous source in sched not reached before new source was commanded'​ (Lucas)
- +    * Hydraulics fault was caused by circuit break as the motor wasn't covered and water got inCollaborative effort of Eric and Brett solved the problem(Lucas)
-2016.295.18:​39:​45.11?​ERROR m5 -908 MARK5 return code 8: parameter error +  ​* GPIB device continues to time-outhowever delay difference is still stable and < 0.3Counters are being monitored on rack camera to make sure that severe drifts don't occur whilst Eric investigates(Lucas). 
- +  * 23:50 UT schedule resumed, lost about 500 GBFirst scan  ​295-2351GPIB still a problem though, reporting massive delay differences every scanClkoff values looks reasonable(Ellen) 
-2016.295.18:​43:​57.60?​ERROR ib   ​-4 ​GPIB Device time-out on response ca +  * 01:04 UT Eric has reset the GPIB device and it is still a problem(Ellen) 
- +  * 01:11 UT Tsys values all overflowing again, restarted CAL again and everything is fineThe CAL has dropped out like this halfway through an experiment before(Ellen) 
-2016.295.18:​44:​20.08?​ERROR ib   -4 GPIB Device time-out on response mg +  * 01:22 UT Jamie has turned the GPIB off so that we are no longer measuring a delay difference because it's wrong anywayKeeping an eye on dbbc=pps_delay instead(Ellen) 
- +  ​* 02:17 UT CAL needed resetting againAnd several other times(Ellen) 
-2016.295.18:​45:​57.60?​ERROR ib   -4 GPIB Device time-out on response ca +  * 07:15 UT CAL reset again(Ross)
- +
-2016.295.18:56:20.50?ERROR ib   -4 GPIB Device time-out on response pp +
- +
-2016.295.18:​56:​55.93?​ERROR sp  -13 This command not supported for your equipment, check equip.ctl+
- +
-2016.295.18:​56:​55.93?​ERROR df -201 Mode must be one of: astro, geo, wastro, test, lba, astro2, or astro3+
- +
-2016.295.18:​56:​55.93?​ERROR sp  -13 This command not supported for your equipmentcheck equip.ctl. +
- +
-2016.295.18:56:​55.93?​ERROR m5 -900 : ENOSYS - not implemented  +
- +
-2016.295.18:​56:​55.93?​ERROR m5 -907 MARK5 return code 7: no such keyword +
- +
-2016.295.18:56:55.93?ERROR m5 -900 : ENOSYS - not implemented ​ +
- +
-2016.295.18:56:​55.93?​ERROR m5 -907 MARK5 return code 7: no such keyword +
- +
-2016.295.18:​56:​55.94?​ERROR m5 -900 : ENOSYS - not implemented ​ +
- +
-2016.295.18:56:​55.94?​ERROR m5 -907 MARK5 return code 7: no such keyword +
- +
-2016.295.18:​56:​55.94?​ERROR m5 -900 : ENOSYS - not implemented ​ +
- +
-2016.295.18:56:​55.94?​ERROR m5 -907 MARK5 return code 7: no such keyword +
- +
-2016.295.18:​56:​56.94?​ERROR sp  -13 This command not supported for your equipment, check equip.ctl+
- +
-2016.295.18:​56:​56.94?​ERROR di -400 IF module position exceeds number of conditioning modules +
- +
-2016.295.18:​56:​56.94?​ERROR sp  -13 This command not supported for your equipment, check equip.ctl. +
- +
-2016.295.18:56:​56.94?​ERROR m5 -900 : ENOSYS - not implemented  +
- +
-2016.295.18:​56:​56.94?​ERROR m5 -907 MARK5 return code 7: no such keyword +
- +
-2016.295.18:56:​56.94?​ERROR m5 -900 : Unknown datasource mark4  +
- +
-2016.295.18:​56:​56.94?​ERROR m5 -908 MARK5 return code 8: parameter error+
  
  
Line 67: Line 28:
 **Hobart 12m** **Hobart 12m**
  
-disk HOB+0098, total data pre-recorded ​1910.604+8114.178+disk HOB+0098, total data pre-recorded ​10024.782GBs
  
-* Experiment Started OK (Lucas).+  ​* Experiment Started OK (Lucas). 
 +  * Schedule halted whilst 26m was down. All scans missed **between** 295-1911 and 295-2016 - ~125 GB missing ​(Lucas).
  
  