 ====== MV003 ====== ====== MV003 ======
  
-All antennas are required onsource for valid data so when Katherine had it's problems this caused the whole experiment to start v late (Lucas).+** EXPERIMENT CANCELLED, DATA INVALID AND DELETED** 
 + 
 +    * All antennas are required onsource for valid data so when Katherine had it's problems this caused the whole experiment to start v late (Lucas)
 +    * Procedure library didn't drudge correctly and almost all mode changes were not done from 0400-0720. Procedure library from mv001 was copied over to all sites and the experiment continued. This did not set off an alarm. First scan with correct proc file No0296.
  
 **Hobart12** **Hobart12**
Line 7: Line 10:
 Disk module HOB+118/​16000,​ start position 0.000GBs Disk module HOB+118/​16000,​ start position 0.000GBs
  
-    * Experiment started late+    * Experiment started late. First scan no0133 @  0400 UT.
  
 **Katherine** **Katherine**
Line 17: Line 20:
             * system monitor reported LO status **UNLOCKED!** however after rxmon was restarted this proved to be incorrect.             * system monitor reported LO status **UNLOCKED!** however after rxmon was restarted this proved to be incorrect.
             * Drives did not turn on, was getting error st -8 power on time-out. On HMI "E STOP" was red, indicating that either water or an animal had tripped the emergency stop and needed to call Mick so he could re-start.             * Drives did not turn on, was getting error st -8 power on time-out. On HMI "E STOP" was red, indicating that either water or an animal had tripped the emergency stop and needed to call Mick so he could re-start.
 +    * First scan no0133 @  0400 UT.
 +
 +* MARK5B time is 0.418.. seconds out of sync with Field system and and cannot be synced despite reboots of FS, MARK5B and dbbc. Attempting to sync the mk5 in fmset results in no change as does '​.'​. Due to this all data is time-stamped >20us offset (aka 0.418 to an insufficient accuracy) and cannot be correlated. All data will be deleted from modules to make way for MV004 AND MV005.
  
 **Yarragadee** **Yarragadee**
Line 24: Line 30:
     * Experiment started late.     * Experiment started late.
             * DBBC needed poser cycling.             * DBBC needed poser cycling.
 +    * First scan no0133 @  0400 UT.
  
  