This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | |||
handover:ohg127 [2020/09/16 19:17] Patrick Yates |
handover:ohg127 [2020/09/17 05:42] (current) Warren Hankey |
||
---|---|---|---|
Line 6: | Line 6: | ||
* Issues with very large clkoff measurement, auto correlations, configuring dbbc. Have restarted / rebooted DBBC, mark5, hobart etc. Warren will look at it in the morning. | * Issues with very large clkoff measurement, auto correlations, configuring dbbc. Have restarted / rebooted DBBC, mark5, hobart etc. Warren will look at it in the morning. | ||
+ | * 0537 - Experiment resumed after dealing with multiple issues. DBBC was in unusable state, apparently due to a fault in the 10 MHz reference cable. Also investigated RF/IF system following up on recentr non-detections. Found a failed cable compensator which has been bypassed. (JMc) | ||
+ | * Ongoing issue - No valid Tsys readings. Origin unclear. (JMc) | ||
**Yarragadee 12m** | **Yarragadee 12m** |