Hobart 12m:

Disk VSN: USN-0085

Data volume at beginning: 0.0 GB

  • 1700UT Experiment started with rfpcn time-out error, have tried restarting Rxmon and Monica numerous times and error is still persisting. Also getting some clock drift. Experiment halted until things are fixed (Tiege)
  • 1730UT Have tried any solutions mentioned on the wiki, usually after 2-3 Rxmon restarts this problem comes right, however, this time it is lingering along with other issues cropping up. The following error “WARNING: 0 : 0x03040003 : 1028 : interrupts error from mark-5b dim or dom ;” has also displayed. I am going to restart Dimino (again) and make sure there are no other funky processes running on mk5hb. (Tiege)
  • 1758UT Experiment has started, however, rfpcn time-out is still being displayed at the start of every scan, I am hesitant to miss any more scans as the rfpcn time-out may be related to the other monica issues people have been reporting. In total I tried restarting Rxmon and monica 6 or so times each, ended dimino process and setup the experiment again, reconfigured dbbc, restarted dbbc, restarted/reconfigured dbbc and mk5 together. (Tiege)
  • 1805UT Seeing the clock drift again (in addition to rfpcn issues) has drifted from 0.260 us to 3.09 us over past 15 mins. going to attempt to fix this now. Experiment being halted again. (Tiege)

Katherine 12m:

Disk VSN: HAY-0062

Data volume at beginning: 0.0 GB

  • 1700UT Experiment started OK. (Tiege)
You could leave a comment if you were logged in.
/home/www/auscope/opswiki/data/attic/handover/r1792.1494871725.txt.gz · Last modified: 2017/05/15 18:08 by Arwin Kahlon