User Tools

Site Tools


handover:r1830

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
handover:r1830 [2018/02/19 04:15]
Jonathan Rogers
handover:r1830 [2018/02/19 18:09] (current)
Jonathan Rogers
Line 7: Line 7:
  
    * 1630UT Experiment started OK (Katie)    * 1630UT Experiment started OK (Katie)
 +   * 1700UT Had error saying:
 +     ​*Warning:​ No PCFS activity for xx minutes.
 +     ​*Check VNC session to see if Field System software is running
 +     ​*Check Network connection.
 +   * I reset the watchdog time, and error went away. The log monitor however doesn'​t seem to know what it is scanning or recording etc. E remote control is working fine, and says that data is being recorded. VNC is also working fine.
  
 **Yarragadee 12m** **Yarragadee 12m**
Line 13: Line 18:
  
    * 1630UT Experiment started OK (Katie)    * 1630UT Experiment started OK (Katie)
 +   * 1700UT Had error saying:
 +     ​*Warning:​ No PCFS activity for xx minutes.
 +     ​*Check VNC session to see if Field System software is running
 +     ​*Check Network connection.
 +   * Fixed itself, started recording fine. 
    
  
/home/www/auscope/opswiki/data/attic/handover/r1830.1519013753.txt.gz · Last modified: 2018/02/19 04:15 by Jonathan Rogers