User Tools

Site Tools


handover:r4689

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
handover:r4689 [2015/05/28 10:21]
liza
handover:r4689 [2015/05/29 22:50] (current)
Vasaant Krishnan
Line 1: Line 1:
 ====== R4689 ====== ====== R4689 ======
- 
  
 <note important>​**Achtung! R1 TRANSFER IN PROGRESS! MONITORING REQUIRED!**</​note>​ <note important>​**Achtung! R1 TRANSFER IN PROGRESS! MONITORING REQUIRED!**</​note>​
 R1 monitoring instructions:​ [[operations:​monitoring.ivs.etransfer|operations:​monitoring.ivs.etransfer]] R1 monitoring instructions:​ [[operations:​monitoring.ivs.etransfer|operations:​monitoring.ivs.etransfer]]
 +
 +
 +R1 Transfer behaved the entire time and looks like it finished happy. (Ellen)
 +
  
  
Line 15: Line 18:
  
 Data volume at beginning: 5052.945 GB Data volume at beginning: 5052.945 GB
 +
 +  * UT 18:27 Windstow active until: 18:31:16 scans missed: 148-1830b (JS)
 +  * UT 02:50 - Halted schedule to restart DBBC. pps_delay value was drifting, which resulted in clock drift. Restarted at 03:06 UT. Missed scans 149-0251 to 149-0258a corresponding to a 7.3 GB deficit (vk)
 +  * UT 03:18 - Restarting the DBBC seems to have worked and the clock differences are clustering at around -0.25 microsec (vk)
 +  * UT 13:03 - Various errors from the pic and disc pos falling slightly behind (~25 GB) so I reset Rxmon. (Ellen)
 +
 +
  
 **Katherine 12m:** **Katherine 12m:**
Line 23: Line 33:
  
 Data volume at beginning: 1.218 GB Data volume at beginning: 1.218 GB
 +
 +Experiment started OK
 +
 +Maser was very slowly drifting over the course for the 24 hours displayed, but stayed between -0.295 and -0.325. (Ellen)
  
 **Yarragadee 12m:** **Yarragadee 12m:**
Line 29: Line 43:
  
 Data volume at beginning: 0.513 GB Data volume at beginning: 0.513 GB
 +
 +UT 18:31 Waiting at limit at start of experiment, missed scan 148-1830b (JS)
  
 Note: IF values were at S-RCP 15, X-LCP 7 I reset these to the nominal S-RCP 10 X-LCP 7 and the attenuations seem fine Note: IF values were at S-RCP 15, X-LCP 7 I reset these to the nominal S-RCP 10 X-LCP 7 and the attenuations seem fine
Line 34: Line 50:
 e-control wasn't connecting but the new one (that we haven'​t used for aaaages) connects fine :-| e-control wasn't connecting but the new one (that we haven'​t used for aaaages) connects fine :-|
  
 +     * 13:09 UT - I decided to try and use the new e-remote just so I could submit checklists. Unlike the normal one it runs, but very slowly. I went looking for Dave's backup version but Nautilus seems to have eaten all the desktop items again... Also the connection seems very flaky, dropping in and out all the time. (Ellen)
  
 +     * 18:10 UT - Experiment ran over onto 2nd module: SHAO-020. So on VSN:​UVLBI-13 there was ~1990 GB and 23 on SHAO-020 from this experiment. (Ellen)