Line 7: Line 7:
      * 18:30 UT - Experiment started ok. (Ellen)      * 18:30 UT - Experiment started ok. (Ellen)
      * 00:34UT - Drive PC failed, had to halt the schedule and restart the Drive PC.  Scans 282-0031 and 282-0037b are there, but may not be ok. (Imogen)      * 00:34UT - Drive PC failed, had to halt the schedule and restart the Drive PC.  Scans 282-0031 and 282-0037b are there, but may not be ok. (Imogen)
 +     * 06:34 UT - SX receiver parameter pressure is 4.9. Warren is going to drive out and fix it. (Ellen)
 +     * 07:20 UT - The pressure is down to 1.8 and the temps are falling slowly back down. (Ellen)
  
 **Katherine** **Katherine**
Line 16: Line 18:
      * 02:20UT - Problem with mk5ke, have to switch to mk5-2ke to record to that until the other mark 5 is fixed. (Imogen)      * 02:20UT - Problem with mk5ke, have to switch to mk5-2ke to record to that until the other mark 5 is fixed. (Imogen)
      * 03:56UT - changed mk5 over to mk5-2ke, began recording again. Autocorrelations on channels 1 and 14 are really not good, but all other channels are fine for now. (Imogen)      * 03:56UT - changed mk5 over to mk5-2ke, began recording again. Autocorrelations on channels 1 and 14 are really not good, but all other channels are fine for now. (Imogen)
 +     * 06:00 UT - Autocorrelation has large spikes in bands 01 and 14. (Ellen)
      * 06:30 UT - Since mk5-2ke is being used the "​clkoff"​ values are wrong and will set off alarms every scan. I changed this in the log monitor to now only beep every scan (Configure > Delay Monitoring > Audible Warning). **The delay differences must be checked manually** using the command "​clkoff-2"​ and comparing that with "​maserdelay"​. (Ellen)      * 06:30 UT - Since mk5-2ke is being used the "​clkoff"​ values are wrong and will set off alarms every scan. I changed this in the log monitor to now only beep every scan (Configure > Delay Monitoring > Audible Warning). **The delay differences must be checked manually** using the command "​clkoff-2"​ and comparing that with "​maserdelay"​. (Ellen)
 +     * 06:30 UT - Autocorrelation still bad in those 2 bands. (Ellen)
 +     * 1200 UT -- Edited ''​midob''​ procedure to call clkoff-2 rather than clkoff. (Dave)
  
 **Yarragadee** **Yarragadee**
Line 24: Line 29:
      * 18:30 UT - Experiment started ok. (Ellen)      * 18:30 UT - Experiment started ok. (Ellen)
      * 21:50 UT - The disc pos is already falling behind, while Ke and Ho are fine. I have noticed that Yg starts recording up to 5 seconds later than it should on some scans. (Ellen)      * 21:50 UT - The disc pos is already falling behind, while Ke and Ho are fine. I have noticed that Yg starts recording up to 5 seconds later than it should on some scans. (Ellen)
 +     * 09:30 UT - Disc pos ~30 GB behind schedule. (Ellen)
  
  
/home/www/auscope/opswiki/data/attic/handover/r4708.1444372353.txt.gz · Last modified: 2015/10/09 06:32 by David Horsley