handover:r4811 [2017/09/28 21:50]
Arwin Kahlon
handover:r4811 [2017/09/29 04:09] (current)
Elizabeth Iles
Line 3: Line 3:
 **Katherine** **Katherine**
  
-Disk VSN: ???? (VSN not being reported by mk5 and Ke ip switch light doesn'​t appear to be working)+Disk VSN: ???? (VSN not being reported by mk5 and Ke ip switch light doesn'​t appear to be working, recording to bank B)
  
 Data Volume at Beginning: 0.000 GB Data Volume at Beginning: 0.000 GB
Line 9: Line 9:
   * 1830UT Experiment started OK (Tiege)   * 1830UT Experiment started OK (Tiege)
   * 2134UT Many "​ALARM:​ error m5 -104 mk5cn: time-out, connection closed"​ errors popping up. Seemed to fix itself, then dropped another round along with some "​ALARM:​ error m5 -900 not while recording or playing"​. Stopping schedule to investigate.   * 2134UT Many "​ALARM:​ error m5 -104 mk5cn: time-out, connection closed"​ errors popping up. Seemed to fix itself, then dropped another round along with some "​ALARM:​ error m5 -900 not while recording or playing"​. Stopping schedule to investigate.
 +  * 21:53UT Had to power cycle mk5ke, in order to get dimino to start again. Upon restarting and checking mk5 banks, there is a fresh module only in bank A? It appears maybe someone removed the disks mid recording and put new ones in? I have started recording to this new bank A module (PKS+0021) note there was originally about 190 GB of data on the mystery module (which is now going to be really hard to identify, however from the webcam it appears there is a 2TB module in bank B [hard to read label, maybe USN-something] but it is not showing up to any commands). (Tiege) 
 +  * 2217UT Called Jamie, he suspects that Mick has changed modules middle of experiment also, going to remain recording to bank A  (Tiege) 
 +  * 0340UT Power outage meant antenna got stuck. Back online by 0350UT. Missed scans  272-0341a,​272-0343b,​272-0346,​272-0349b. (Liz)
  