Line 6: Line 6:
  
    * 1830UT - Experiment started OK (Tiege)    * 1830UT - Experiment started OK (Tiege)
-   * 2005UT - Two clock jumps at Ke one after the pother. Going to monitor and see if it stabilises ​npw. (did this last experiment). (Tiege)+   * 2005UT - Two clock jumps at Ke one after the other. Going to monitor and see if it stabilises ​now. (as with this previous ​experiment). (Tiege)
    * 1534UT - MK5 crash / DIMino Crash (JS)    * 1534UT - MK5 crash / DIMino Crash (JS)
    * 1612UT - MK5 reset. (JS)    * 1612UT - MK5 reset. (JS)
       * Lost scans 264-1531 through 264-1610       * Lost scans 264-1531 through 264-1610
-   * 1612UT - FS locked up during `midob` yg FS was temporarily stalled at the same time but didn't die ... hmmm ... resetting KE FS (JS)+   * 1612UT - FS locked up during `midob` ​resetting FS (JS) 
 +      * yg FS was temporarily stalled ​& unresponsive to commands ​at the same time but resumed without dying .... hmmmmm
    * 1626UT FS reset, resuming experiment at scan 264-1632 (JS)    * 1626UT FS reset, resuming experiment at scan 264-1632 (JS)
       * Lost scans 264-1531 through 264-1628       * Lost scans 264-1531 through 264-1628
-   *  +   ​* ​1626UT ​ "​ALARM:​ scan_check reports Mark5 data format problem"​ this is likely due to a syncerr_eq_3 across the previous partial recording (264-1628) monitoring for further issues before escalating (JS) 
-   ​* ​+   ​* ​1638UT receive another "m5 -104 mk5cn" error, halted and restarted MK5 (JS) 
 +      * affected scan 264-1641b 
 +    * 1647UT MK5 reset hasn't solve the issues, still plagued by "m5 -104 mk5cn" error whenever a scan ends, despite DIMino running and responding (JS) 
 +   * 1710UT after calling Jamie, the conclusion is that there are bad HDD in the current module causing read/write lag that the field system doesn'​t like. The data should be recording ok, but the errors will persist (JS) 
 **Yarragadee 12m** **Yarragadee 12m**
  
/home/www/auscope/opswiki/data/attic/handover/r4860.1537547480.txt.gz · Last modified: 2018/09/21 16:31 by Pradyumna Kiran Kummamuru