Line 3: Line 3:
 **Hobart 26m** **Hobart 26m**
  
-Disk VSN: HOB+0025+Disk VSN: HOB+0025 ​
  
 Data volume at beginning: 775.920 GB Data volume at beginning: 775.920 GB
 +
 +  * 17:15UT getting error qy -1 error in response from counter. Tried restarting with '​counter'​ command. No response when issuing clkoff and maserdelay commands. Called on-call (Warren), to attempt to fix (Bryn)
 +  * 17:30UT experiment started on time.
 +  * 17:37UT WARNING: error ib   -4 gpib device time-out on response ca. Error likely related to previous, trying to reset with counter does nothing. Manual reset of GPIB device might be needed (had a similar issue to this a few months ago) Waiting until staff on site to fix. (Bryn)
 +  * 0829UT Large delay (~0.98 us) fmset issued between scans (JS)
  