User Tools

Site Tools


katherine_todo

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
katherine_todo [2014/04/07 06:18]
Jamie McCallum
katherine_todo [2014/07/26 06:20]
Jamie McCallum
Line 2: Line 2:
  
     * Phase cal testing (temperature stabilisation?​ Bad filters?)     * Phase cal testing (temperature stabilisation?​ Bad filters?)
-    * DBBC service - check cables, internal connections,​ bad boards)+    * <​del> ​DBBC service - check cables, internal connections,​ bad boards) 
 +        * Apparently working as of 25/7/14 after replacing Fila OUT, reseating stack & PCI7200 card & cables. ​  
 +    * earthing of DBBC and MK5 units using proper earth connections
     * DBBC cont cal - tune for ~2-5% CONT CAL, 5-10% pulsed CAL     * DBBC cont cal - tune for ~2-5% CONT CAL, 5-10% pulsed CAL
         * CONT CAL seems to be triggered when PULSED CAL is? Check wiring on spare board?         * CONT CAL seems to be triggered when PULSED CAL is? Check wiring on spare board?
     * Y-factor tests - get all CAL factors via DBBC.      * Y-factor tests - get all CAL factors via DBBC. 
-    * control room temp sensors - MoniCA+    * <del>control room temp sensors - MoniCA
     * twister cable suspender     * twister cable suspender
-    * fix UPS +    * <del>fix UPS</​del>​ 
-    * pedestal fan +    * pedestal ​and maser room fan, fix/replace 
-    * webcam clean +    * <del>webcam clean</​del>​ 
-    * Upgrade mk5-2ke +    * <del>Upgrade mk5-2ke. Replace module back plane 
-    * Back up all PCs +    * <del>Back up all PCs 
-    * Maser service. +    * <del>Maser service.</​del>​ 
-    * tidy ptz wiring +    * <del>tidy ptz wiring 
-    * clean all sky cam lens+    * <del>clean all sky cam lens</​del>​
     * check for rodents in genset     * check for rodents in genset
 +    * generator battery charger reduce electrolyte boiling
     * feed temp/press sensor     * feed temp/press sensor
     * weed control     * weed control
     * insect proofing of the hub     * insect proofing of the hub
-    * pedestal base flange seal +    * <del>pedestal base flange seal</​del>,​ recoat with paving paint 
-    * grooves in concrete foundation to promote drainage+    * <del>grooves in concrete foundation to promote drainage</​del>​
     * remove rust from container and paint     * remove rust from container and paint
  
Line 31: Line 34:
   * Pedestal   * Pedestal
     * <​del>​Evict wildlife</​del>​     * <​del>​Evict wildlife</​del>​
 +    * drain spare conduit
     * <​del>​Modify controller setting to accept remote resets, and test</​del>​     * <​del>​Modify controller setting to accept remote resets, and test</​del>​
   * Antenna structure   * Antenna structure
Line 38: Line 42:
   * Site   * Site
     * <​del>​Remove rubbish</​del>​     * <​del>​Remove rubbish</​del>​
 +    * weeding and mowing
 +    * shelter above container
   * hardware   * hardware
     * <​del>​Confirm full set of spares</​del>,​ record serial numbers     * <​del>​Confirm full set of spares</​del>,​ record serial numbers
Line 55: Line 61:
       * <​del>​Determine gross pointing offsets and obtain a zeroth-order model (Jim)</​del>​       * <​del>​Determine gross pointing offsets and obtain a zeroth-order model (Jim)</​del>​
     * <​del>​Measure SEFD at all bands. Should be ~2500 Jy</​del>​     * <​del>​Measure SEFD at all bands. Should be ~2500 Jy</​del>​
-    * Fringe check to Hobart+    * <del>Fringe check to Hobart</​del>​
   * Software   * Software
     * Confirm PCFS can talk to:     * Confirm PCFS can talk to:
Line 105: Line 111:
       * Dehydrator       * Dehydrator
       * Dehumidifier       * Dehumidifier
-      * <del>Eye-bolt in the cone</​del>​ +      * Eye-bolt in the cone 
-      * <del>Wash Subreflector</​del>​+      * Wash Subreflector
       * Doors in Hub, <​del>​trim</​del>​ and cutouts, <​del>​fit</​del>​       * Doors in Hub, <​del>​trim</​del>​ and cutouts, <​del>​fit</​del>​
       * Rod and hook for retrieving fall arrester       * Rod and hook for retrieving fall arrester
 +      * eye bolt for fall arrester
       * <​del>​Phase Cal xdB - Sband 1dB</​del>​       * <​del>​Phase Cal xdB - Sband 1dB</​del>​
       * UPS       * UPS
       * Maser battery PLL fault       * Maser battery PLL fault
 +      * run a sych and 100MHz rg58 coax
       * Camera       * Camera
         * <​del>​Lightning arrestor</​del>​         * <​del>​Lightning arrestor</​del>​
 +        * focus
         * <​del>​Lens:​ clean and check</​del>​         * <​del>​Lens:​ clean and check</​del>​
       * <​del>​Install window blind</​del>​s       * <​del>​Install window blind</​del>​s
Line 128: Line 137:
       * <​del>​Label equipment</​del>​       * <​del>​Label equipment</​del>​
       * Label supension files containing equipment manuals       * Label supension files containing equipment manuals
 +      * oil change in az gear boxes and check/fix cause of leak
 +      * sort generator battery and charging system
 +      * oil change generator
 +      * painting pedestal rust spots
 +      * painting container rust spots
 +      * Thermal sensors calibrate
 +      * Sort mark5 earthing and other problems
 +      * Sort counter 3
 +      * install additional switch
 +      * wire in PDUs
 +      * LAN cabling
 +      * install IR light properly
 +      * check lightning arresters
       *        * 
 +
 +Bunnings
 +  * pedestal Fans
 +  * Halogen globes 500W
 +  * Paraflood Low energy
 +  * rags
 +  * 9V batteries
 +  * Vac cleaner bags. for shop vac
 +  * 3 in one oil for fan motors
 +  * 
 +
 +
 +Car parts NT
 +  * diesel oil
 +  * diesel filter
 +  * fan bearing grease
 +
 +Take
 +  * Switch 24port 1Gbps
 +
 +
 +
/home/www/auscope/opswiki/data/pages/katherine_todo.txt · Last modified: 2014/07/26 06:21 by Jamie McCallum