User Tools

Site Tools


observing:ragrav

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
observing:ragrav [2017/04/14 07:42]
Elizabeth Iles
observing:ragrav [2017/04/22 06:18] (current)
Elizabeth Iles
Line 68: Line 68:
 "Take out attenuation in X-band, IF rack "Take out attenuation in X-band, IF rack
 ifpic=*,​*,​15,​15,​0,​0</​code>​ ifpic=*,​*,​15,​15,​0,​0</​code>​
-    - Modify the DBBC frequencies to include LCP channels: <​code>​define ​ dbbc014 ​      ​16273135148x ​           ​+    - Modify the DBBC frequencies to include LCP channels, **note the 16273135148x number will be 0000000000x at the start** and is written later (I imagine the time it was executed?​) ​: <​code>​define ​ dbbc014 ​      ​16273135148x ​           ​
 bbc01=798.75,​a,​4.00 bbc01=798.75,​a,​4.00
 bbc02=798.50,​a,​4.00 bbc02=798.50,​a,​4.00
Line 86: Line 86:
 lo=lob,​7600.00,​usb,​rcp,​off lo=lob,​7600.00,​usb,​rcp,​off
 enddef</​code>​ enddef</​code>​
-    - Lastly, add the checkmk5 procedure: <​code>​define ​ checkmk5 ​     16273141501x  ​<​---(this number is 0000000x at the start)+    - Lastly, add the checkmk5 procedure: <​code>​define ​ checkmk5 ​     16273141501x  ​
 scan_check scan_check
 !+1s !+1s
Line 114: Line 114:
 ==== PC Field System ==== ==== PC Field System ====
  
-  - Start the field system in the VNC session and start the schedule <​code>​schedule=<​schedule>,#​1</​code>​+  - Start the field system in the VNC session. If you cannot get the field system to run, you'll need to power cycle the pcfsyg through the Internet power switch. Once the pcfsyg comes back online after a boot, ssh into it and start the vnc server by typhing ''​vncserver''​ into the terminal. Now, open the vnc session to the pcfsyg ​and start the schedule <​code>​schedule=<​schedule>,#​1</​code>​
   - You may get error messages like this<​code>​ERROR st  -28 UT1TimeOffset non-zero, see value above.</​code>​. Silence them with the command <​code>​tnx=st,​-28</​code>​   - You may get error messages like this<​code>​ERROR st  -28 UT1TimeOffset non-zero, see value above.</​code>​. Silence them with the command <​code>​tnx=st,​-28</​code>​
   - It's a good idea to monitor total power levels into the DBBC during the observations. Do this with <​code>​iread@!,​10s</​code>​   - It's a good idea to monitor total power levels into the DBBC during the observations. Do this with <​code>​iread@!,​10s</​code>​
/home/www/auscope/opswiki/data/attic/observing/ragrav.1492155722.txt.gz · Last modified: 2017/04/14 07:42 by Elizabeth Iles