Current Issues | Current Issues | ||
- | * New PCFS at Hobart (thanks Jamie) | + | * Problems with drive hydraulics on 26m, cancelled today's experiment (RD1603). |
+ | |||
+ | * New PCFS at Hobart is working great (thanks Jamie). Has anyone had any problems? | ||
* Maser maintenance at both Katherine and Yarragadee currently, hence Brett is not at the Observatory. Warren is at Mt Pleasant Tuesdays to Thursdays and occasionally Mondays. | * Maser maintenance at both Katherine and Yarragadee currently, hence Brett is not at the Observatory. Warren is at Mt Pleasant Tuesdays to Thursdays and occasionally Mondays. | ||
- | * CRDS82 - "still getting ve error: ERROR ch -308 ve total power integrator overflow" - what was this and was it fixed Bryn? | + | * CRDS82 - "still getting ve error: ERROR ch -308 ve total power integrator overflow" - Bryn, what was this and was it fixed? |
* R4734 - Yarragadee: consistent offset between mark 5 and other computers of 0.1 - 0.4 visible in fmset with no sync error, could not be fixed. Caused by power failure affecting GPS receiver (new UPS installed) - had to change to Hobart's. Fixed itself 4+ hours later. Is there any way to fix this other than hope? | * R4734 - Yarragadee: consistent offset between mark 5 and other computers of 0.1 - 0.4 visible in fmset with no sync error, could not be fixed. Caused by power failure affecting GPS receiver (new UPS installed) - had to change to Hobart's. Fixed itself 4+ hours later. Is there any way to fix this other than hope? | ||
Line 19: | Line 21: | ||
* R1735 - A couple of instances where recorder started ~ 7-10 seconds before onsource at both Katherine and Yarragadee. | * R1735 - A couple of instances where recorder started ~ 7-10 seconds before onsource at both Katherine and Yarragadee. | ||
- | * High system temperatures - run systemp12 again to make sure it wasn't just one dodgy reading. Monitor make note of how many scans were affected by high tsys values. | + | * High system temperatures - run systemp12 again to make sure it wasn't just one dodgy reading. Monitor and make note of how many scans were affected by consistent high tsys values. |
* Anything else to note? | * Anything else to note? | ||