Chair/Presenting: Bryn
In Attendance:
Apologies:
Absent:
___
Agenda:
General Issues
LBA this weekend - keep skype open and check the LBA chat, let atnf people know when you come on shift
Check disk space before starting the experiment
Issues from Handover notes
AUG031 ke and yg fs lockup - required reboots
HOB006 Ho tsys overflowing again - is there an issue with the CAL causing it to drop out mid experiments?
Hb not coming out of wind stows properly - caused by either long wind stows or immediate wind stow after release
R4762 ke ALARM: error s5 -104 rfpcn: time-out, connection closed occurred a lot during this experiment
t2113 ke MET sensor disconnected - GA upgrading GNSS receiver & new interface is required
Yg and Ke webcams faulty/no connections
Dynamic observing @ ke: ALARM: error m5 -900 not while recording or playing
“ ERROR ch -4 Device v3 timed-out on response from MATCN ” means that something is wrong with the mk4 VCs and the mk4 rack (white one with 'VC' lights) needs to be restarted manually at Mt P. This error appeared after setupsx when changing the 26m back to the mk4 from the mk5/dbbc. The rack can be reset by turning off, waiting then turning on again and waiting (red lights everywhere until you setupsx again). The on/off switch is at the top of the rack. If this doesn't fix the matcn error then you needs to call Brett.