Chair: Ross

Attended:

Apologies:

Absent:

General Issues

  • Yg said they don't get information about the disk space required for an experiment from the new schedule format (.vex experiments?).
  • Yg also said that sometimes the module spreadsheet is not updated (w.r.t. which modules are assigned to experiments).

Handover Issues

  • r4848 (ke) Can't access maserke vnc, but can ping the machine.
  • crds96 (ke) received “Warning: error tc -301 continuous cal not enabled for dbbc” for each scan. Fixed continuous cal not enabled error by changing cont_cal=off to cont_cal=on in the setup01 function of the procedure file, based off the previous crds95 procedure file.
  • aov024 (ho) Was getting “ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater ”. Ran sy=run setcl offset into the newsmerd fs window (oprin)
  • r1847 (ke) noticed coordinates had not changed, checked to see the FS had crashed. Restarted FS and the schdule, missing data from 0729 UT till 08:22 UT. It appears log monitor had also stopped responding.
  • r1847 (yg) Humidity sensor appears to not be working.