User Tools

Site Tools


operations:agenda2018_07_26

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
operations:agenda2018_07_26 [2018/07/26 03:05]
Patrick Yates
operations:agenda2018_07_26 [2018/08/09 03:21] (current)
Simin Salarpour
Line 1: Line 1:
-**Chair:​** ​Patrick+**Chair:​** ​Katie
  
-**Attended:​** ​KatieRossMas, Tiege, Lucas, ​JamieAtifurPrad+**Attended:​** ​JamieLuciaPatrick, Lucas, ​SiminJesseRoss, Tiege, Atifur
  
-**Apologies:​** ​Simin+**Apologies:​** ​Mas
  
-**Absent:​** ​Lucia+**Absent:​** ​Prad
  
 **General Issues** **General Issues**
 +    * Yg wind sensor?
 +      * Something in the wiring, ​ disconnected at the moment (under investigation). Keep an eye on the weather radar. Cal Yg if you see wind picking up. Monica?
 +    * Ke mk5 problems?  ​
 +      * Crashing and stalling. Maybe going to change it. Maybe swap to mk52. Under investigation.
 +    * AUM exp went well, have fringes. ​
 +    * Masers for ke and yg not working. ​
 +      * ke visible on one network but not the other...yg not sure. Under investigation.
 +    * Audio on ops8 - drops in and out.
 +    * Half of baby monitor missing.
 +    * Ho 26 L band receiver being repaired. Cold head being assessed in Mlb.
 +    * Ho 26 maybe one of the breaks has a problem? ​
 +    * hobart 12, for flogit, the proc files weren'​t getting sent. The proc file is essentially empty, its a '​dummy'​.
 +    * occasionally an error with comments, and thats why flogit won't work sometimes.
  
-  * Sound on ops8 still patchy? 
        
 **Handover Issues** ​ **Handover Issues** ​
  
-  * aov25+  * R4853 
-      * **ho:** Receiver heating up again - seems to be happening regularly?​ +      * **ke:​**  ​ES Oven V Katherine maser fluctuate from blue colour (0.9) to red colour (25.8). Brett came to auscope room and had a look at this problem. We sent an email the history file of maser KE to Anton and Jamie (mas) 
-  * r1852/​aov25/​r1851:​ +      * Open issues with the maser being investigated. Noone can go do some repairs inside the maser another reason why it is important to keep an eye on the maser. 
-      * **ke:** Difference between Mk5/Fs of 1 secondHappened twice - to sync or not to sync? + 
-  * r1852: +  
-      * **yg:** mk5cn not responding, JMc rebooted mk5-2yg + 
-      * **yg:** ntupdate not correcting offset +
-  * r4851: +
-      * **ke:** field system hung after ``disk2file`` command +
-  * r1851: +
-      * **ke:** Autocorrelation spectra were weird. DBBC card died, Mick replaced it. +
-      * **ke:** mk5ke also died (wouldn'​t come back after reboot), but started working after Mick tried a different power cable, and swapped back+
/home/www/auscope/opswiki/data/attic/operations/agenda2018_07_26.1532574303.txt.gz · Last modified: 2018/07/26 03:05 by Patrick Yates