**Chair:** Lim | **Chair:** Lim | ||
- | **Attended:** | + | **Attended:** Momtaz Simin, Mas, Tiege, Patrick, Jamie, Katie |
- | **Apologies:** | + | **Apologies:** Ross, Earl, Jay, Lucas |
**Absent:** | **Absent:** | ||
Line 12: | Line 12: | ||
* Please remember to create handover note page during setup. | * Please remember to create handover note page during setup. | ||
* No connection to Yg and Hb maser. | * No connection to Yg and Hb maser. | ||
+ | * Go to pcfs terminate the e remote control and restart if cannot connect. | ||
+ | * End message, if problem exists, please mention/describe the error. | ||
**Handover Issues** | **Handover Issues** | ||
Line 23: | Line 25: | ||
CRD102: | CRD102: | ||
* Ho: 1307UT - fmset puts the field system time 6.2 seconds ahead of the Mark5 and Computer time, this seems to result in scans ending (and starting) ~5 seconds ahead of schedule (when going off the log time). We are in the last 50 mins of the experiment so I am going to leave as is rather than spend 25 mins restarting machines and end up losing more data than would be (potentially) saved. (Tiege) | * Ho: 1307UT - fmset puts the field system time 6.2 seconds ahead of the Mark5 and Computer time, this seems to result in scans ending (and starting) ~5 seconds ahead of schedule (when going off the log time). We are in the last 50 mins of the experiment so I am going to leave as is rather than spend 25 mins restarting machines and end up losing more data than would be (potentially) saved. (Tiege) | ||
- | * | + | * on going issue. Jamie will solve it tomorrow. Get the 26m to log the time difference |
R1894: | R1894: | ||
* Yg: pcfsyg disk filled up 15 minutes before experiment started. Needed to remove some old epi/png files from the auto_corr_test directory. (Tiege) | * Yg: pcfsyg disk filled up 15 minutes before experiment started. Needed to remove some old epi/png files from the auto_corr_test directory. (Tiege) | ||
- | * | + | * Cronjob to clean up directory everyday |
+ | * New machine coming in a few months with new system. | ||
+ | * Might still need to use the old system. | ||
AOV035: | AOV035: | ||
Line 33: | Line 37: | ||
* Fixed by resetting TTY distributor with “reset” switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) | * Fixed by resetting TTY distributor with “reset” switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) | ||
* 1725UT - wx command not working. (Patrick) | * 1725UT - wx command not working. (Patrick) | ||
+ | * Path failure. | ||
+ | * Ups failed (lost power) | ||
+ | * Working now. |