operations:agenda2019_05_16 [2019/05/16 02:46]
Lim Chin Chuan
operations:agenda2019_05_16 [2019/05/16 03:14] (current)
Lim Chin Chuan
Line 1: Line 1:
 **Chair:** Lim **Chair:** Lim
  
-**Attended:​** ​+**Attended:​** ​Momtaz Simin, Mas, Tiege, Patrick, Jamie, Katie
  
 **Apologies:​** Ross, Earl, Jay, Lucas **Apologies:​** Ross, Earl, Jay, Lucas
Line 12: Line 12:
     * Please remember to create handover note page during setup.     * Please remember to create handover note page during setup.
     * No connection to Yg and Hb maser.     * No connection to Yg and Hb maser.
 +    * Go to pcfs terminate the e remote control and restart if cannot connect.
 +    * End message, if problem exists, please mention/​describe the error. ​
  
 **Handover Issues** **Handover Issues**
Line 23: Line 25:
 CRD102: CRD102:
    * Ho: 1307UT - fmset puts the field system time 6.2 seconds ahead of the Mark5 and Computer time, this seems to result in scans ending (and starting) ~5 seconds ahead of schedule (when going off the log time). We are in the last 50 mins of the experiment so I am going to leave as is rather than spend 25 mins restarting machines and end up losing more data than would be (potentially) saved. (Tiege)    * Ho: 1307UT - fmset puts the field system time 6.2 seconds ahead of the Mark5 and Computer time, this seems to result in scans ending (and starting) ~5 seconds ahead of schedule (when going off the log time). We are in the last 50 mins of the experiment so I am going to leave as is rather than spend 25 mins restarting machines and end up losing more data than would be (potentially) saved. (Tiege)
-     ​* ​+     ​* ​on going issue. Jamie will solve it tomorrow. Get the 26m to log the time difference
  
 R1894: R1894:
    * Yg: pcfsyg disk filled up 15 minutes before experiment started. Needed to remove some old epi/png files from the auto_corr_test directory. (Tiege)    * Yg: pcfsyg disk filled up 15 minutes before experiment started. Needed to remove some old epi/png files from the auto_corr_test directory. (Tiege)
-     ​* ​+     ​* ​Cronjob to clean up directory everyday 
 +     * New machine coming in a few months with new system. 
 +     * Might still need to use the old system.
  
 AOV035: AOV035:
Line 33: Line 37:
      * Fixed by resetting TTY distributor with “reset” switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett)      * Fixed by resetting TTY distributor with “reset” switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett)
    * 1725UT - wx command not working. (Patrick)    * 1725UT - wx command not working. (Patrick)
 +     * Path failure. ​
 +     * Ups failed (lost power)
 +     * Working now.