** next week's chair: ** Katie | ** next week's chair: ** Katie | ||
- | **Attended:** | + | **Attended:** Tiege, Lucas, Patrick, Prad, Lim, Guifre, Earl |
**Apologies:** | **Apologies:** | ||
Line 11: | Line 11: | ||
**General Issues** | **General Issues** | ||
+ | |||
+ | * Yg: Monica generating 20 GB/hour in error conditions. | ||
+ | * Yg: eRemoteCtrl isn't showing right date and timing of current scan. | ||
+ | * Maybe could use backup control instead, eRemote control doesn't seem to give much? Nice pie graphs? Can also use other log monitor which greps important information out. | ||
+ | * Search for field system backup. | ||
+ | * Ho needs to have cry pump on all night to keep temperature reasonable. Even with pump on may be around 80-90K. Not much life left in pump. | ||
Line 17: | Line 23: | ||
* AUA056 | * AUA056 | ||
* Ho/Yg: auto-correlation did not update, missing checkmk5 block in the procedure file. | * Ho/Yg: auto-correlation did not update, missing checkmk5 block in the procedure file. | ||
+ | * slogit didn't run, got emailed around. Manually drudged, checkmk5 not added. | ||
* AOV039 | * AOV039 | ||
* Yg: Monica log file /usr2/oMlog oMonica.log was writing flat out at 20 GB per hour. This was due to constant errors logging that Monica couldn't connect to weather on localhost port 5000. A restart of Monica server on pcfsyg fixed the problem. | * Yg: Monica log file /usr2/oMlog oMonica.log was writing flat out at 20 GB per hour. This was due to constant errors logging that Monica couldn't connect to weather on localhost port 5000. A restart of Monica server on pcfsyg fixed the problem. | ||
- | * R1912 | + | * R4910 |
- | * Yg: Monica log file filled up disk, as above. | + | * Yg: Field system had locked up; missed scans from 248-2130b. |
* R1911 | * R1911 | ||
- | * Yg: ERC displaying wrong DOY and UT. | ||
* Yg: Waiting at limit for several scans. Field system had forced antenna to limit and would not take new source commands. Restarted the field system and schedule at scan 253-1025a. | * Yg: Waiting at limit for several scans. Field system had forced antenna to limit and would not take new source commands. Restarted the field system and schedule at scan 253-1025a. | ||
+ | * Due to old version of field system maybe. |