 **Chair:** Prad **Chair:** Prad
  
-**Attended:​** ​+**Attended:​** ​Jay, Jamie, Tiege, Simin, Mas, Katie, Lim, Momtaz, Ross, Lucas
  
 **Apologies:​** Patrick, Earl **Apologies:​** Patrick, Earl
Line 9: Line 9:
  
 **General Issues** **General Issues**
-    ​+ 
 +    * Please don't forget to start a handover notes page. 
 +    * Live map of the Ke weather has been down - Jamie will have a look/any ideas from observers to fix it? 
 +    * Ke connection getting closed regularly - power glitches? 
 +    * Try ensuring the 26m pressure is pumped down during the day. 
 +    * Adding Ke back to the calendar. ​
  
    
Line 19: Line 24:
 **AUA051** **AUA051**
  
-    * No SCHED/VEX file on ftp server.+    * No SCHED/VEX file on ftp server ​- one-off incident. Unlikely to repeat. For AUA/CRDS experiments have a look in advance to make sure things are alright (available on ftp server).
  
  
 **R1889** **R1889**
  
-    * **Ke** Something appears wrong with the cross-over switches currently at Ke. They are currently just displaying numbers. Tiege supposedly fixed this by halting the schedule and running xodirect, this returned an rfpcn timeout. Needed to restart Rxmon on pcfske, then run xodirect in the field system to fix. Unsure if this was just being displayed wrong (hence Rxmon needing a restart) or if the switches were not actually in '​direct'​+    * **Ke** Something appears wrong with the cross-over switches currently at Ke. They are currently just displaying numbers. Tiege supposedly fixed this by halting the schedule and running xodirect, this returned an rfpcn timeout. Needed to restart Rxmon on pcfske, then run xodirect in the field system to fix. Unsure if this was just being displayed wrong (hence Rxmon needing a restart) or if the switches were not actually in '​direct' ​- Possible power glitch at Ke. 
  
 **R4888** **R4888**
  
-       * **Ke** Compared to Yg, we are lagging 3 times more data at Ke. 15 as compared to 5 (Tiege).+       * **Ke** Compared to Yg, we are lagging 3 times more data at Ke. -15 as compared to -5 (Tiege). ​Rxmon?
  
  
  
  