User Tools

Site Tools


operations:currentissues

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
operations:currentissues [2016/08/08 23:10]
Jim Lovell [Humidity monitor at Yarragadee]
operations:currentissues [2018/01/25 03:20]
Jamie McCallum [iread does not return a target power level/DBBC attenuation at maximum or isdx settings wrong in proc file]
Line 1: Line 1:
 ====== Current Issues ====== ====== Current Issues ======
 +
 +===== Yarragadee IF rack =====
 +
 +The PIC in the IF rack at Yg has a problem that prevents diode switching and hence Tsys measurements. The 
 +preob procedure in station.prc has been edited to comment out systemp12. Will need re-enabling when tsys is back (Jim)
 +
 +===== Yarragadee Network =====
 +
 +If the network connection to Yarragadee dies, the VPN could need reseting:
 +
 +  * [[operations:​yg_VPN_reset|How to reset the Yarragadee VPN]]
  
 ===== Humidity monitor at Yarragadee ===== ===== Humidity monitor at Yarragadee =====
Line 5: Line 16:
 The weather sensor at Yarragadee is currently away for repair (humidity sensor is broken). Weather is still being logged but from a separate sensor that is not connected to the Field System. Until our sensor is repaired and returned, there is an extra procedure to go through to recover the weather information:​ The weather sensor at Yarragadee is currently away for repair (humidity sensor is broken). Weather is still being logged but from a separate sensor that is not connected to the Field System. Until our sensor is repaired and returned, there is an extra procedure to go through to recover the weather information:​
  
-  * [[operations:​documentation:​yg_manual_weather|Manual extraction and login of Yg weather data]]+  * [[operations:​documentation:​yg_manual_weather|Manual extraction and logging ​of Yg weather data]]
  
 (added 14th Oct 2015, updated 9 Aug 2016) (added 14th Oct 2015, updated 9 Aug 2016)
Line 166: Line 177:
 pfmed: exit pfmed: exit
 </​code>​ </​code>​
 +
 +Note that for Hobart26, the settings will be different (due to the LO frequencies of 8080/2020 MHz rather than 7600/1900 for the 12ms). e.g
 +
 +<​code>​
 +pfmed
 +pfmed: pf,r1593ke
 +pfmed: ed,ifdsx
 +</​code>​
 +<​code>​
 +ifa=1,​agc,​2,​40000
 +ifb=4,​agc,​1,​48000
 +ifc=2,​agc,​2,​32500
 +ifd=2,​agc,​2,​35000
 +</​code>​
 +<​code>​
 +pfmed: exit
 +</​code>​
 +
  
 ===== DBBC computer hangs/​crashes ===== ===== DBBC computer hangs/​crashes =====
/home/www/auscope/opswiki/data/pages/operations/currentissues.txt · Last modified: 2018/06/19 01:38 by Tiege McCarthy