This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
operations:currentissues [2016/08/08 23:10] Jim Lovell [Humidity monitor at Yarragadee] |
operations:currentissues [2018/01/25 03:20] Jamie McCallum [iread does not return a target power level/DBBC attenuation at maximum or isdx settings wrong in proc file] |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Current Issues ====== | ====== Current Issues ====== | ||
+ | |||
+ | ===== Yarragadee IF rack ===== | ||
+ | |||
+ | The PIC in the IF rack at Yg has a problem that prevents diode switching and hence Tsys measurements. The | ||
+ | preob procedure in station.prc has been edited to comment out systemp12. Will need re-enabling when tsys is back (Jim) | ||
+ | |||
+ | ===== Yarragadee Network ===== | ||
+ | |||
+ | If the network connection to Yarragadee dies, the VPN could need reseting: | ||
+ | |||
+ | * [[operations:yg_VPN_reset|How to reset the Yarragadee VPN]] | ||
===== Humidity monitor at Yarragadee ===== | ===== Humidity monitor at Yarragadee ===== | ||
Line 166: | Line 177: | ||
pfmed: exit | pfmed: exit | ||
</code> | </code> | ||
+ | |||
+ | Note that for Hobart26, the settings will be different (due to the LO frequencies of 8080/2020 MHz rather than 7600/1900 for the 12ms). e.g | ||
+ | |||
+ | <code> | ||
+ | pfmed | ||
+ | pfmed: pf,r1593ke | ||
+ | pfmed: ed,ifdsx | ||
+ | </code> | ||
+ | <code> | ||
+ | ifa=1,agc,2,40000 | ||
+ | ifb=4,agc,1,48000 | ||
+ | ifc=2,agc,2,32500 | ||
+ | ifd=2,agc,2,35000 | ||
+ | </code> | ||
+ | <code> | ||
+ | pfmed: exit | ||
+ | </code> | ||
+ | |||
===== DBBC computer hangs/crashes ===== | ===== DBBC computer hangs/crashes ===== |