This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
operations:documentation.dbbcsetupivs [2011/11/22 03:35] Jim Lovell |
operations:documentation.dbbcsetupivs [2016/05/16 12:48] (current) Bryn Emptage |
||
---|---|---|---|
Line 5: | Line 5: | ||
* ''dbbc_config_file_geo.txt'' for R1 and R4 geodesy | * ''dbbc_config_file_geo.txt'' for R1 and R4 geodesy | ||
+ | * ''dbbc_config_file_geo_16.txt'' for AUSTRAL sessions | ||
* ''dbbc_config_file_APSG_CRF.txt'' for APSG, CRDS and CRF geodesy | * ''dbbc_config_file_APSG_CRF.txt'' for APSG, CRDS and CRF geodesy | ||
* ''dbbc_config_file_T2_OHIG.txt'' for T2 and OHIG | * ''dbbc_config_file_T2_OHIG.txt'' for T2 and OHIG | ||
Line 32: | Line 33: | ||
You now need to set up the IF system. The commands to do this depend on the IVS observation and the station. | You now need to set up the IF system. The commands to do this depend on the IVS observation and the station. | ||
- | For R1, R4 and RDV experiments on **Hobart** and **Katherine** they should be: | + | For R1, R4, CRF, CRDS, AUSTRAL and RDV experiments on they should be: |
<code> | <code> | ||
dbbcifa=1,agc,1 | dbbcifa=1,agc,1 | ||
Line 41: | Line 42: | ||
</code> | </code> | ||
- | For R1, R4 and RDV experiments on **Yarragadee** they should be: | ||
- | <code> | ||
- | dbbcifa=1,agc,4 | ||
- | dbbcifb=4,agc,1 | ||
- | dbbcifc=2,agc,2 | ||
- | dbbcifd=2,agc,2 | ||
- | reg=1,17,4 | ||
- | reg=5,17,4 | ||
- | reg=1,19,4 | ||
- | reg=5,19,4 | ||
- | </code> | ||
- | This is because Yg has a non-standard configuration of conditioning modules. CoMo A handles the upper X-band frequencies while CoMo B handles the lower 4. This is the opposite of other sites. | ||
- | For APSG, CRDS, CRF, OHIG and T2 experiments, they should be: | + | For APSG, OHIG and T2 experiments, for all stations they should be: |
<code> | <code> | ||
dbbcifa=1,agc,1 | dbbcifa=1,agc,1 | ||
Line 63: | Line 52: | ||
</code> | </code> | ||
- | The target values for the total power readings is 56000. this can be checked by the command dbbcif[abcd]. If the levels are too high or low, then adjust the attenuation on the IF box. Note that the levels on IF C (dbbcifc) are a bit low. Don't worry about it. | + | Recommended DBBC power levels can be found [[hardware:dbbc.targetifpower|here]]. Current target values for the total power readings is 56000. this can be checked by the command: ifa, ifb, ifc or ifd. If the levels are too high or low, then adjust the attenuation on the IF box. Note that the levels on IF C (e-remote control command: ifc) are a bit low. Don't worry about it. |
- | + |