 If you can't connect to the DBBC VNC server, the DBBC may have died. In which case, follow these notes on [[operations:​documentation:​dbbc_restart|Recovering from a DBBC Failure]] If you can't connect to the DBBC VNC server, the DBBC may have died. In which case, follow these notes on [[operations:​documentation:​dbbc_restart|Recovering from a DBBC Failure]]
  
-In ''​C:​\DBBC_CONF\''​ are several configuration files for different experiment types. The default configuration is kept in ''​dbbc_config_file_104.txt'' ​(for Hb and Yg) and ''​dbbc_config_file_102.txt''​ (for Ke) and this will be loaded when the server software is started. ​+In ''​C:​\DBBC_CONF\''​ are several configuration files for different experiment types. The default configuration is kept in ''​dbbc_config_file_104.txt''​ and this will be loaded when the server software is started. ​
  
-Check to see if a program called ''​DBBC2 ​ControlDDC ​v104_2.exe''​ is running ​for Hb and Ke, or ''​DBBC2 ControlDDC v102.exe''​ for Ke. If it's not running, start it. There'​s a link to it from the desktop. (Don't have two instances running.) +Check to see if a program called ''​DBBC2 ​Control DDC v104_2.exe''​ is running. If it's not running, start it. There'​s a link to it from the desktop. (Don't have two instances running.) 
-<note important>​Make sure you are running v104_2 of the DBBC Control software ​at Hb and Yg, and v102 at Ke.</​note>​ +<note important>​Make sure you are running v104_2 of the DBBC Control software.</​note>​ 
-If the DBBC has had a power cycle or if there have been timing problems, or if you just want to be cautious, say "​y"​ when asked if you want to reconfig with the defaults. Configurations will take about 2 minutes. ​+If the DBBC has had a power cycle or if there have been timing problems, or if you just want to be cautious, say "​y"​ when asked if you want to reconfig with the defaults. Configurations will take about 2 minutes. ​The DBBC window will stop at "​Waiting for communication from port 4000" or something to that effect. You will need to enter the command listed below in eRemotecontrol to proceed further. (Arwin)
  
 <note important>​If you did reconfigure the DBBC, synchronise the DBBC to the station pps with the following command from eRemoteControl ​ <note important>​If you did reconfigure the DBBC, synchronise the DBBC to the station pps with the following command from eRemoteControl ​