User Tools

Site Tools


operations:documentation.dbbcsetupivs_v2

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
operations:documentation.dbbcsetupivs_v2 [2015/01/23 04:41]
cjordan [Setting the IFs]
operations:documentation.dbbcsetupivs_v2 [2016/10/08 16:08] (current)
Jesse Swan
Line 30: Line 30:
 Enter Command: pps_sync Enter Command: pps_sync
 </​code>​ </​code>​
 +
 +During observations,​ the log monitor will ring an alarm if the internal delay in the dbbc has changed. This is automatically tested every scan. To trigger the command yourself, use
 +''​dbbc=pps_delay=1''​.
  
 ===== Setting the IFs ===== ===== Setting the IFs =====
Line 36: Line 39:
 You now need to set up the IF system. The commands to do this depend on the IVS observation. You now need to set up the IF system. The commands to do this depend on the IVS observation.
  
-For R1, R4, AUSTRAL, CRF, CRDS and RDV experiments they should be:+For R1, R4, AUSTRAL, CRF, CRDS, AUG, AUA and RDV experiments they should be:
 <​code>​ <​code>​
 ifa=1,agc,1 ifa=1,agc,1
Line 47: Line 50:
  
  
-For APSG, OHIG and T2 experiments they should be:+For APSG, OHIG, AOV and T2 experiments they should be:
 <​code>​ <​code>​
 ifa=1,agc,1 ifa=1,agc,1
Line 72: Line 75:
 The target power levels are listed on the [[hardware:​dbbc.targetifpower|Recommended DBBC IF Power Levels]] page. The current power level (and target) can be checked by the command if[abcd]. If the levels are too high or low, then adjust the attenuation on the IF box.  The target power levels are listed on the [[hardware:​dbbc.targetifpower|Recommended DBBC IF Power Levels]] page. The current power level (and target) can be checked by the command if[abcd]. If the levels are too high or low, then adjust the attenuation on the IF box. 
  
-'''​Chris: I don't think the following has been an issue for some time. Candidate for removal?'''​+**Chris: I don't think the following has been an issue for some time. Candidate for removal?** 
 There is a known issue where the target levels loaded by the DBBC through load=dbcc... are incorrect. For now, the workaround is to specify the target power levels in the ifdsx section of the proc file. There is a known issue where the target levels loaded by the DBBC through load=dbcc... are incorrect. For now, the workaround is to specify the target power levels in the ifdsx section of the proc file.
/home/www/auscope/opswiki/data/attic/operations/documentation.dbbcsetupivs_v2.1421988071.txt.gz · Last modified: 2015/01/23 04:41 by cjordan