operations:documentation.errors [2017/09/27 06:29]
Jamie McCallum [Antenna stuck | Warning: error st -27 computer acu time difference exceeded 0.25 seconds, see value above.]
operations:documentation.errors [2017/09/27 06:29] (current)
Jamie McCallum [Antenna stuck | Warning: error st -27 computer acu time difference exceeded 0.25 seconds, see value above.]
Line 44: Line 44:
 Normally this error can be ignored, but there was an additional error: Normally this error can be ignored, but there was an additional error:
  
 +<​code>​
 WARNING: error st  -10 rampepochtime not -1 when preparing to load, check antenna is in "​operate"​. WARNING: error st  -10 rampepochtime not -1 when preparing to load, check antenna is in "​operate"​.
 +</​code>​
  
  Error presented as drive status not ready, with drives green in HMI. HMI was unresponsive - could not turn drives off. Antenna=operate and Antenna=open both return Antenna OK, but don't work. The clock on the right of HMI interface on cnsshb (CURRENT TIME UT1) was not updating.  Error presented as drive status not ready, with drives green in HMI. HMI was unresponsive - could not turn drives off. Antenna=operate and Antenna=open both return Antenna OK, but don't work. The clock on the right of HMI interface on cnsshb (CURRENT TIME UT1) was not updating.