operations:documentation.ivs.newstart_v3_fs9.10.5 [2012/11/13 03:08]
Jim Lovell [Starting]
operations:documentation.ivs.newstart_v3_fs9.10.5 [2018/09/25 22:09] (current)
Pradyumna Kiran Kummamuru
Line 66: Line 66:
 >  * [[operations:​documentation.DBBCSetupIVS_9.10.5|DBBC Setup]] >  * [[operations:​documentation.DBBCSetupIVS_9.10.5|DBBC Setup]]
  
-At the start of every scan, the pcfs executes the ''​setupsx'' ​or ''​setup8f''​ procedure (depending on experiment type) which sets the DBBC input channels, filters and BBC frequencies (and configues the Mark5). However, it's a good idea to execute it now so that a recorder test can be made:+At the start of every scan, the pcfs executes the ''​setupsx''​ which sets the DBBC input channels, filters and BBC frequencies (and configues the Mark5). However, it's a good idea to execute it now so that a recorder test can be made:
   * For R1, R4, RD, RDV, T2, ANZ, CRDS, CRF, OHIG:<​code>​setupsx</​code>​   * For R1, R4, RD, RDV, T2, ANZ, CRDS, CRF, OHIG:<​code>​setupsx</​code>​
-  * For AUST, CONT:<​code>​setup8f</​code>​ +  
-''​setupsx'' ​(or ''​setup8f''​) ​calls ''​ifdsx''​ which sets up the DBBC Conditioning module inputs, filters and power levels, then ''​dbbcsx8''​ (or ''​dbbcsx4''​ for a 4 MHz DBBC mode)  which sets the BBC frequencies. Then if you type:+''​setupsx''​ calls ''​ifdsx''​ which sets up the DBBC Conditioning module inputs, filters and power levels, then ''​dbbcsx8''​ (or ''​dbbcsx4''​ for a 4 MHz DBBC mode)  which sets the BBC frequencies. Then if you type:
 <​code>​iread</​code>​ <​code>​iread</​code>​
 You will see what the current Conditioning module settings are. Output format is: You will see what the current Conditioning module settings are. Output format is:
Line 86: Line 86:
 == Mark5 Recorder setup == == Mark5 Recorder setup ==
 Next the Mark5 recorder needs to be prepared for the observations. ​ Next the Mark5 recorder needs to be prepared for the observations. ​
 +
 +If the allocated Mk5 module contains data:
 +
 +Check the remaining space on the module and the compare with the space required for the experiment from the summary file. disk_pos can be used for such purpose. **Do NOT delete any data** unless it is something done as test recording.
  
 If you need to swap disk modules: If you need to swap disk modules: