User Tools

Site Tools


operations:documentation:dbbc_restart

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
operations:documentation:dbbc_restart [2013/03/14 02:40]
Jim Lovell created
operations:documentation:dbbc_restart [2015/08/27 01:32] (current)
Imogen Jones [Restarting the DBBC]
Line 21: Line 21:
       * Katherine: ​ ipske.phys.utas.edu.au       * Katherine: ​ ipske.phys.utas.edu.au
       * Yarragadee: ​ ipsyg.phys.utas.edu.au       * Yarragadee: ​ ipsyg.phys.utas.edu.au
-    * You can access them via their web pages, or by telnet. The username is '​administrator'​ and the password is the standard root password (see the whiteboard in the control room). You need to turn off the DBBC, wait about 30 sec, then turn it on again. From the telnet interface (for Katherine): <​code>​telnet ipske.phys.utas.edu.au+    * You can access them via their web pages, or by telnet. The username is '​administrator' ​(didn'​t work for me, I had to use '​admin'​) ​and the password is the standard root password (see the whiteboard in the control room). You need to turn off the DBBC, wait about 30 sec, then turn it on again. From the telnet interface (for Katherine): <​code>​telnet ipske.phys.utas.edu.au
 [password] [password]
 /Off 5 /Off 5
Line 29: Line 29:
 </​code>​ </​code>​
   * You should see the DBBC come to life on the camera and after the PC has booted, you'll be able to connect via the VNC session. To log in, select the user ''​dbbc''​. The password is written on the whiteboard in the control room at Mt Pleasant and in the AuScope control room.   * You should see the DBBC come to life on the camera and after the PC has booted, you'll be able to connect via the VNC session. To log in, select the user ''​dbbc''​. The password is written on the whiteboard in the control room at Mt Pleasant and in the AuScope control room.
-  * +  * The DBBC software then needs starting and the hardware configuring. See [[operations:​documentation:​lba_observing_software_setup|Observing software setup]] 
 +  * Once the DBBC is happy again, make sure the Field System can talk to it <​code>​setup01</​code>​ 
 +  * Then re-commence the schedule, e.g. <​code>​schedule=v252aike</​code>​
/home/www/auscope/opswiki/data/attic/operations/documentation/dbbc_restart.1363228814.txt.gz · Last modified: 2013/03/14 02:40 by Jim Lovell