Internet Power Switches (IPS)

There are three IPSs that can can be used to reboot computers in the event they are unreachable using normal (ssh/vnc) methods.

They are:

ipshb.phys.utas.edu.au
ipske.phys.utas.edu.au
ipsyg.phys.utas.edu.au

They have a fairly straightforward web interface. The username for all three is 'administrator', and the password should be the standard root password, however one may be non standard. If you run into any problems you should consult your on-call person.

You may receive a 'Server is Busy' and/or 'There may be someone else logged in to the ips' error. In this case you can still telnet in:

telnet ipshb.phys.utas.edu.au
*******
/Off 5
/On 5
/X

In this case we are restarting plug 5.

After this you will need to restart and reconfigure the DBBC, instructions are here:

http://auscope.phys.utas.edu.au/opswiki/doku.php?id=operations:documentation.dbbcsetupivs_9.10.5

In econtrol to get the DBBC talking to the mk5:

setupsx

In pcfs[hb|ke|yg] sync everything:

fmset

In econtrol reset the counters for clkoff and maserdelay:

counter

A clkoff and maserdelay would also be wise to check the delays are OK and stable.

List of ports available for on/off/boot at Katherine:

Plug	Name	Status	On	Off	Boot	Default
1	pcfske	ON				ON
2	mk5ke	ON				ON
3	timeke	ON				ON
4	windke	ON				ON
5	DBBC	ON				ON
6	Camera	ON				ON
7	ExteriorLight	OFF				OFF
8	AgilentUSBHub ON                        ON