User Tools

Site Tools


operations:r4455_notes

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
operations:r4455_notes [2010/11/04 23:11]
Jim Lovell
operations:r4455_notes [2011/10/26 06:37] (current)
Line 1: Line 1:
 The DBBC sometimes loses a channel. First spot-check done at 308/22:50 and found three channels to be suspect: 1 (X-band 1u), 9 (X-band 1l) and 11 (S-band 9u): The DBBC sometimes loses a channel. First spot-check done at 308/22:50 and found three channels to be suspect: 1 (X-band 1u), 9 (X-band 1l) and 11 (S-band 9u):
  
-{{:​operations:​r4455hb_308_2250_314935091200.png?​500|}}+{{:​operations:​r4455hb_308_2250_314935091200.png?​400|}}
  
 After reconfiguring DBBC, before scan 308-2256, all autocorrelations were fine: After reconfiguring DBBC, before scan 308-2256, all autocorrelations were fine:
  
-{{:​operations:​r4455hb_308_2259_334582476800.png?​500|}}+{{:​operations:​r4455hb_308_2259_334582476800.png?​400|}} 
 + 
 +Another spot-check at 309/03:12 showed bad looking autocorrelations in channels 1, 4, 9, 11 and 14: 
 + 
 +{{:​operations:​r4455hb_309_0312_585992089600.png?​400|}} 
 + 
 +Autocorrelations look good again in scan 309-0328a. 
 + 
 +Checked again at 309/03:35. Bad spectra in channels 1, 9 and 11: 
 + 
 +{{:​operations:​r4455hb_309_0535_724613580800.png?​400|}} 
 + 
 +Data should be good from scan 309-0544a 
 + 
 + 
 + 
 +[[How to check autocorrelation spectra]]
  
  
/home/www/auscope/opswiki/data/attic/operations/r4455_notes.1288912292.txt.gz · Last modified: 2011/10/26 06:37 (external edit)