This shows you the differences between two versions of the page.
Next revision | Previous revision Next revision Both sides next revision | ||
deformation:testsetup1 [2012/08/29 03:22] Jim Lovell created |
deformation:testsetup1 [2012/08/29 04:48] Jim Lovell [PC Software] |
||
---|---|---|---|
Line 16: | Line 16: | ||
* From the LoggerNet CD | * From the LoggerNet CD | ||
* Installed the software (key printed on CD) | * Installed the software (key printed on CD) | ||
- | * | + | |
+ | * Ran LoggerNet and started through setup wizard | ||
+ | * Selected CR1000, named it Array 1 | ||
+ | * Selected IP Port as Communication Setup | ||
+ | * Now need to give it an IP address... | ||
+ | * Will configure over serial connection | ||
+ | * USB to serial connector required driver from manufacturer: | ||
+ | * Manual at at http://sabrent.com/product-manuals/USB-TO-SERIAL-CABLES_Manual.pdf | ||
+ | * Want driver for SBT-USC6K from http://www.sabrent.com/downloads.php | ||
+ | * Followed installation instructions | ||
+ | * Came up on COM3, 9600 baud, 8 bit, parity none, stop bits 1, flow control none. | ||
+ | * Connected power to logger via DC power-pack. No luck. Direct connection to battery works | ||
+ | * MAC address for Array 1 00d02c04b057 |