handover:crds72 [2014/08/21 14:04] liza |
handover:crds72 [2014/08/21 21:35] liza |
||
---|---|---|---|
Line 5: | Line 5: | ||
Ho: | Ho: | ||
* erc Status Monitor window shows wrong time: 1969.264.23.0.00 while it is really (according to formatter, FS, computer) is 2014.233.08.20.00. Execution of commands happens according to real time. | * erc Status Monitor window shows wrong time: 1969.264.23.0.00 while it is really (according to formatter, FS, computer) is 2014.233.08.20.00. Execution of commands happens according to real time. | ||
+ | * At around 16:45, cryogenic show signs of warm-up: T(70K phase)=84K, T(20K)=65K, He pressure goes down recently, but currently 305 psi | ||
+ | * Frequent error: "Error being ignored: error qk -211 tsys value for device ic overflowed or was less than zero." and "Error being ignored: error ch -308 vd total power integrator overflow" | ||
+ | * | ||
- | Hb: | + | Hb: |
+ | * Peaks autocorrelation bandpasses in ch 14, 15 -- RFI | ||
+ | * recording to NRCAN-05 | ||
Ke: | Ke: | ||
* Persistent problem: WARNING: error an -103 pointing computer tracking errors are too large. ; WARNING: error qo -301 warning: onsource status is slewing! | * Persistent problem: WARNING: error an -103 pointing computer tracking errors are too large. ; WARNING: error qo -301 warning: onsource status is slewing! | ||
+ | * recording to NRCAN-07 | ||
Yg: | Yg: | ||
+ | * Internet connection is flaky, ERC loses connection every now and then, so often that even filling the checklist is problematic | ||
+ | * Descending slope in the autocorrelation bandpass in channel 15 -- RFI | ||
+ | * recording to USN-0205 | ||