handover:t2111 [2016/06/22 04:46] Jamie McCallum |
handover:t2111 [2016/06/22 04:55] Jamie McCallum |
||
---|---|---|---|
Line 3: | Line 3: | ||
**Katherine** | **Katherine** | ||
- | Module: HART-015, start pos: 0 GB | + | Modules: HART-015, start pos: 0 GB and HAY-0021/960/1024, start pos 0 GB. |
* 17:30UT - Experiment started ok. (Nick) | * 17:30UT - Experiment started ok. (Nick) | ||
- | * 0330-0445 - Problems with mk5ke, networking. | + | * 0330-0445 - Problems with mk5ke, networking. HART-015 developed an error, all recordings failed with "XLRappend append error". Problem persisted through reboot and power cycles, also present when using jive5ab. recover did not correct the problem. (JMc) |
* Experiment resumed at 0445 using mk5-2ke. /usr2/control/mk5ad.ctl edited to use this recorder, clkoff edited in t2111ke to use the correct counter. (JMc) | * Experiment resumed at 0445 using mk5-2ke. /usr2/control/mk5ad.ctl edited to use this recorder, clkoff edited in t2111ke to use the correct counter. (JMc) | ||
+ | * Experiment recorded across two modules in the two mk5 units (HART-015 and HAY-0021) | ||
**Yarragadee** | **Yarragadee** |