   * **Tsys: S-band Tsys 50 to 70K**   * **Tsys: S-band Tsys 50 to 70K**
   * **Tsys: X-band Tsys 50 to 70K**   * **Tsys: X-band Tsys 50 to 70K**
-  ​* **check the receiver position with ''​rxp''​** Should be -256, +248, +18 (x,y,z)+<note important>  ​* **check the receiver position with ''​rxp''​** Should be -256, +248, +18 (x,y,z). The values may be off by 2-3 mm which is the measurement noise. The 26m live page will have the receiver listed (left side)as "​S/​X"​ if all is well.</​note>​
   * **Cryogenics**. The command ''​cryomon''​ will return information on the S/X cryogenics. The lines to look out for are the ''​pres''​ and ''​70k''​ values...   * **Cryogenics**. The command ''​cryomon''​ will return information on the S/X cryogenics. The lines to look out for are the ''​pres''​ and ''​70k''​ values...
     * **Cryogenics:​ Vacuum pressure less than 3.5**. The Vacuum pressure in the S/X dewar should be below this value (measured in microns of Mercury). If it increases above this value, it indicates a leak. Let Brett know. e.g. this readout indicates a vacuum pressure of 1.227 <​code>​2014.126.09:​00:​46.53/​rx/​17(pres),​on,​a,​on,​on,​on,​off,​locked,​1.227</​code>​     * **Cryogenics:​ Vacuum pressure less than 3.5**. The Vacuum pressure in the S/X dewar should be below this value (measured in microns of Mercury). If it increases above this value, it indicates a leak. Let Brett know. e.g. this readout indicates a vacuum pressure of 1.227 <​code>​2014.126.09:​00:​46.53/​rx/​17(pres),​on,​a,​on,​on,​on,​off,​locked,​1.227</​code>​