Line 12: Line 12:
     * **Cryogenics:​ Vacuum pressure less than 3.5**. The Vacuum pressure in the S/X dewar should be below this value (measured in microns of Mercury). If it increases above this value, it indicates a leak. Let Brett know. e.g. this readout indicates a vacuum pressure of 1.227 <​code>​2014.126.09:​00:​46.53/​rx/​17(pres),​on,​a,​on,​on,​on,​off,​locked,​1.227</​code>​     * **Cryogenics:​ Vacuum pressure less than 3.5**. The Vacuum pressure in the S/X dewar should be below this value (measured in microns of Mercury). If it increases above this value, it indicates a leak. Let Brett know. e.g. this readout indicates a vacuum pressure of 1.227 <​code>​2014.126.09:​00:​46.53/​rx/​17(pres),​on,​a,​on,​on,​on,​off,​locked,​1.227</​code>​
     * **Cryogenics:​ 70K stage temperature below 65K**. The S/X dewar contains a 20K and a 70K stage. If the 70K stage temperature exceeds about 65K, this indicates the receiver is warming up and needs attention. Contact Brett. e.g. this readout indicates a 70K stage temperature of 167K (not good!) <​code>​2014.126.09:​01:​49.97/​rx/​1F(70k),​on,​a,​on,​on,​on,​off,​locked,​167.0</​code>​     * **Cryogenics:​ 70K stage temperature below 65K**. The S/X dewar contains a 20K and a 70K stage. If the 70K stage temperature exceeds about 65K, this indicates the receiver is warming up and needs attention. Contact Brett. e.g. this readout indicates a 70K stage temperature of 167K (not good!) <​code>​2014.126.09:​01:​49.97/​rx/​1F(70k),​on,​a,​on,​on,​on,​off,​locked,​167.0</​code>​
-    * **Cryogenics:​ Helium supply pressure above 275 psi**. Use a [[software:​monica_26m_cryo|MONICA session on ''​newsmerd''​ to monitor the Helium supply pressure]]. If it drops below 275 psi, call Brett! The plot might be up in the vnc newsmerd session (Desktop 4).+    * **Cryogenics:​ Helium supply pressure above 275 psi**. Use a [[software:​monica_26m_cryo|MONICA session on ''​newsmerd''​ to monitor the Helium supply pressure]]. If it drops below 275 psi, call Brett! ​**Bear in mind that according to the gas law ''​pv = nrt''​ the pressure will go down on a cold night.** It is advisable to only call Brett if the pressure is quite below 275 and or there have been massive sudden dips in pressure indicating a leak. The plot might be up in the vnc newsmerd session (Desktop 4).
   * **Log Monitor audio check button sounds audible beep**. Make sure you can hear the alarms   * **Log Monitor audio check button sounds audible beep**. Make sure you can hear the alarms
   * **Skype**. Make sure Skype is running to allow a chat session with all participating sites plus the on-call person   * **Skype**. Make sure Skype is running to allow a chat session with all participating sites plus the on-call person
   * **System: Check and update [[operations:​handover|Handover]] and [[operations:​currentissues|Current Issues]] wiki pages**   * **System: Check and update [[operations:​handover|Handover]] and [[operations:​currentissues|Current Issues]] wiki pages**
   * **System: Any problems or concerns logged**. Anything else of note? Put it in the log   * **System: Any problems or concerns logged**. Anything else of note? Put it in the log