This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
handover:aua021 [2017/05/10 00:03] Warren Hankey |
handover:aua021 [2017/05/10 09:03] (current) Arwin Kahlon |
||
|---|---|---|---|
| Line 15: | Line 15: | ||
| * 2351UT synced formatter time to station time - noticed that several LO were unlocked on the VC rack at approximately 2325UT - tried resetting the VC rack and TTY distributor. Still seeing errors for one VC - assuming all data prior to this bad due to formatter time issue. (Bryn) | * 2351UT synced formatter time to station time - noticed that several LO were unlocked on the VC rack at approximately 2325UT - tried resetting the VC rack and TTY distributor. Still seeing errors for one VC - assuming all data prior to this bad due to formatter time issue. (Bryn) | ||
| * 0000UT VC rack issues fixed. Data should be good again. | * 0000UT VC rack issues fixed. Data should be good again. | ||
| + | * 0843UT Alarm: Previous source in the schedule not reached before new source was commanded. A quick scan of the logs revealed that there was (Lucas): | ||
| + | * 2017.130.08:43:32.92#antcn#Error: Antenna reported error from last command (0) | ||
| + | * 2017.130.08:43:32.96#antcn#Antenna control system Problem with the antenna drives | ||
| + | * Antenna was fixed by following notes [[http://auscope.phys.utas.edu.au/opswiki/doku.php?id=operations:26mdrives | here]]. Only required the first bit so drives must have got confused in a little loop. Maybe due to the small scan times (Lucas). | ||
| + | * Scans effected 130-0844 through to 130-0902 (Lucas) | ||
| **Katherine 12m:** | **Katherine 12m:** | ||