Hobart 26m:

Disk VSN: HOB+0094

Data volume at beginning: 0.0 GB

  • 1730UT Exp started OK. (Ross)
  • Device v3 timed-out on response from MATCN not noticed until setup at 1700UT since Jim observing (Ross)
  • 1810UT Mostly working after a trip to Mt pleasant, except for a single vc which is still dodgy after several restarts (Ross)
  • 1820UT Tried again to reset but made it worse, stable again after 1826UT (Ross)
  • 1852UT Returned to UTAS and errors have returned included LO unlocked lights on 2 of the vcs, waiting until morning now (Ross)
  • 2351UT synced formatter time to station time - noticed that several LO were unlocked on the VC rack at approximately 2325UT - tried resetting the VC rack and TTY distributor. Still seeing errors for one VC - assuming all data prior to this bad due to formatter time issue. (Bryn)
  • 0000UT VC rack issues fixed. Data should be good again.
  • 0843UT Alarm: Previous source in the schedule not reached before new source was commanded. A quick scan of the logs revealed that there was (Lucas):
    • 2017.130.08:43:32.92#antcn#Error: Antenna reported error from last command (0)
    • 2017.130.08:43:32.96#antcn#Antenna control system Problem with the antenna drives
    • Antenna was fixed by following notes here. Only required the first bit so drives must have got confused in a little loop. Maybe due to the small scan times (Lucas).
    • Scans effected 130-0844 through to 130-0902 (Lucas)

Katherine 12m:

Disk VSN: IAAE-018

Data volume at beginning: 0.0 GB

  • 1730UT Exp started OK. (Ross)

Yarragadee 12m:

Disk VSN: PKS+0021

Data volume at beginning: 0.0 GB

  • 1730UT Exp started OK. (Ross)