handover:mv004 [2017/01/14 00:42] Lucas Hyland |
handover:mv004 [2017/01/14 11:45] (current) Lucas Hyland |
||
|---|---|---|---|
| Line 13: | Line 13: | ||
| Module HOB+0130, recorded 1043.582 GBs previously. | Module HOB+0130, recorded 1043.582 GBs previously. | ||
| + | |||
| + | * Power outage, antenna got stuck after the system recovered: | ||
| + | * halt | ||
| + | * disk_record=off | ||
| + | * antenna=off | ||
| + | * terminate | ||
| + | * in timeke, HMI, 'reset drives', wait until both comms stati are green | ||
| + | * fs | ||
| + | * proc=mv004ke | ||
| + | * setup01 | ||
| + | * antenna=open | ||
| + | * antenna=operate | ||
| + | * source=stow | ||
| + | And it moved. Then I restarted the schedule. Generator status was 'in auto-off' so I assumed the power came on without any problems. | ||